English
Language : 

MAX1617A Datasheet, PDF (2/18 Pages) Maxim Integrated Products – Remote/Local Temperature Sensor with SMBus Serial Interface
Remote/Local Temperature Sensor
with SMBus Serial Interface
ABSOLUTE MAXIMUM RATINGS
VCC to GND ..............................................................-0.3V to +6V
DXP, ADD_ to GND ....................................-0.3V to (VCC + 0.3V)
DXN to GND ..........................................................-0.3V to +0.8V
SMBCLK, SMBDATA, ALERT, STBY to GND ...........-0.3V to +6V
SMBDATA, ALERT Current .................................-1mA to +50mA
DXN Current .......................................................................±1mA
ESD Protection (SMBCLK, SMBDATA,
ALERT, Human Body Model) ......................................... 4000V
ESD Protection (other pins, Human Body Model)..............2000V
Continuous Power Dissipation (TA = +70°C)
QSOP (derate 8.30mW/°C above +70°C) .....................667mW
Operating Temperature Range .........................-55°C to +125°C
Junction Temperature ......................................................+150°C
Storage Temperature Range .............................-65°C to +165°C
Lead Temperature (soldering, 10sec) .............................+300°C
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
ELECTRICAL CHARACTERISTICS
(VCC = +3.3V, TA = 0°C to +85°C, unless otherwise noted.)
PARAMETER
CONDITIONS
MIN TYP MAX UNITS
ADC AND POWER SUPPLY
Temperature Resolution (Note 1) Monotonicity guaranteed
8
Bits
Initial Temperature Error,
Local Diode (Note 2)
Temperature Error, Remote Diode
(Notes 2 and 3)
Temperature Error, Local Diode
(Notes 1 and 2)
Supply-Voltage Range
TA = +60°C to +100°C
TA = 0°C to +85°C
TR = +60°C to +100°C
TR = -55°C to +125°C
Including long-term drift
-2
-3
-3
-5
TA = +60°C to +100°C -2.5
TA = 0°C to +85°C
-3.5
3.0
2
°C
3
3
°C
5
2.5
°C
3.5
5.5
V
Undervoltage Lockout Threshold
Undervoltage Lockout Hysteresis
VCC input, disables A/D conversion, rising edge
2.60 2.80 2.95
V
50
mV
Power-On Reset Threshold
POR Threshold Hysteresis
VCC, falling edge
1.0
1.7
2.5
V
50
mV
Standby Supply Current
Logic inputs
forced to VCC
or GND
SMBus static
Hardware or software standby,
SMBCLK at 10kHz
3
10
µA
4
Average Operating Supply Current
Auto-convert mode, average 0.25 conv/sec
measured over 4sec. Logic
inputs forced to VCC or GND. 2.0 conv/sec
35
70
µA
120
180
Conversion Time
Conversion Rate Timing Error
Remote-Diode Source Current
DXN Source Voltage
Address Pin Bias Current
From stop bit to conversion complete (both channels)
94
125
156
ms
Auto-convert mode
-25
25
%
DXP forced to 1.5V
High level
Low level
80
100
120
µA
8
10
12
0.7
V
ADD0, ADD1; momentary upon power-on reset
160
µA
2 _______________________________________________________________________________________