MAX14821 Datasheet, PDF (19/31 Pages) Maxim Integrated Products – IO-Link Device Transceiver
MAX14821
IO-Link Device Transceiver
Register Functionality
The device has four 8-bit-wide registers for configuration and monitoring (Table 1).
Table 1. Register Summary
REGISTER R1 R0
Status
00
CQConfig 0 1
DIOConfig 1 0
Mode
11
R1/R0 = Register address.
D7
WuInt
RxFilter
DoInv
RST
D6
DoFaultInt
HiSlew
DoAv
WuIntEn
D5
DiLvl
C/Q_N/P
DoN/P
DoFault
D4
QLvl
C/Q_PP
DoPP
C/QFault
D3
C/QFaultInt
C/QDEn
DoEn
UV24
D2
UV33Int
Q
DoBit
OTemp
D1
UV24Int
RxDis
LiDis
UV33En
D0
OTempInt
C/QLoad
DiLoad
LDO33Dis
Bit
D7
D6
D5
D4
Bit Name
WuInt DoFaultInt
DiLvl
QLvl
Read/Write
R
R
R
R
POR State
0
0
X
X
Reset Upon Read
Yes
Yes
No
No
X = Unknown. These bits are dependent on the DI logic and C/Q inputs.
Status Register [R1, R0] = [0,0]
D3
C/QFaultInt
R
0
Yes
D2
UV33Int
R
0
Yes
D1
UV24Int
R
0
Yes
D0
OTempInt
R
0
Yes
The Status register reflects the logic levels of C/Q and DI and shows the source of interrupts that cause an IRQ
hardware interrupt. The IRQ interrupt is asserted when an alarm condition (OTemp, UV33Int, UV24, C/QFault,
DoFault, WuInt) is detected. All bits in the Status register are read-only. The interrupt bits return to the default state
after the Status register is read. If a C/Q or DO fault condition persists, the associated interrupt bits are immediately
set after the Status register is read.
BIT
NAME
DESCRIPTION
D7
Wulnt
Wake-Up Interrupt Request. WuInt is set when an IO-Link wake-up request pulse is
detected on C/Q and the WuIntEn bit in the Mode register is set. IRQ asserts when
WuInt is set to 1. Read the Status register to clear the WuInt bit and deassert IRQ.
D6
DoFaultInt
DO Fault Interrupt. DoFaultInt interrupt bit and DoFault bit (in the Mode register) are
set when a fault condition occurs on the DO driver output. The device registers a fault
condition when a short circuit or voltage fault is detected on DO (see the DO Fault
Detection section for more information). IRQ asserts when DoFaultInt is 1. Read the
Status register to clear the DoFaultInt bit and deassert IRQ.
D5
DiLvl
DI Logic Level. The DiLvl bit mirrors the current logic level at the DI input. It is the
inverse of the LI output and is always active regardless of the state of the LiDis bit (Table
2). DiLvl does not affect IRQ. DiLvl is not changed when the Status register is read.