LE
CLK
DIN
DOUT
tCL
tCH
tDH
tDS
D7
tLW
tLS
tCP
D0
tDO
D7
OE
OUT_
Figure 3. 4-Wire Serial-Interface Timing Diagram
LE
tLRF
OUT_
LE
OUT_
CLK
OUT_
CLK
OUT_
tLRR
tCRF
tCRR
Figure 4. LE and CLK to OUT_ Timing
tOEW
tOEF
tf
tOER
80%
20%
tr
LED Fault Detection (MAX16808)
The MAX16808 includes circuitry that detects open-cir-
cuit LEDs automatically. An open-circuit fault occurs
when an output is sinking current less than approxi-
mately 50% of the programmed current flows. Open cir-
cuits are checked just after the falling edge of OE. The
fault data is latched on the rising edge of LE and is
shifted out when new LED data is loaded into the out-
put latches from the shift register. If one or more output
ports are detected with an open-circuit fault, the D6
and D5 bits of DOUT go high. If no open-circuit faults
are detected, D6 and D5 are set to low. The data in the
other 6 bit positions in DOUT are not altered. Fault sta-
tus is shifted out on DOUT for the first two rising edges
of the clock after the falling edge of LE (see Figure 5).
LE is normally taken high after all 8 bits of new LED
OE
LE
CLK
DOUT
Figure 5. Fault Timing
D7 D6 D5 D4
FAULT STATUS BITS
______________________________________________________________________________________ 17