Table 8. Slave Address Decoding (ADD0
and ADD1)
ADD0
GND
GND
GND
High-Z
High-Z
High-Z
VCC
VCC
VCC
ADD1
GND
High-Z
VCC
GND
High-Z
VCC
GND
High-Z
VCC
ADDRESS
0011 000
0011 001
0011 010
0101 001
0101 010
0101 011
1001 100
1001 101
1001 110
Note: High-Z means that the pin is left unconnected and floating.
A
B
C
D
EF
G
tLOW tHIGH
SMBCLK
H
I
J
K
SMBDATA
tSU:STA tHD:STA
tSU:DAT
A = START CONDITION
B = MSB OF ADDRESS CLOCKED INTO SLAVE
C = LSB OF ADDRESS CLOCKED INTO SLAVE
D = R/W BIT CLOCKED INTO SLAVE
Figure 4. SMBus Read Timing Diagram
E = SLAVE PULLS SMBDATA LINE LOW
F = ACKNOWLEDGE BIT CLOCKED INTO MASTER
G = MSB OF DATA CLOCKED INTO MASTER
H = LSB OF DATA CLOCKED INTO MASTER
A
B
C
D
EF
G
tLOW tHIGH
SMBCLK
tSU:STO tBUF
I = ACKNOWLEDGE CLOCK PULSE
J = STOP CONDITION
K = NEW START CONDITION
H
IJ
K
LM
SMBDATA
tSU:STA tHD:STA
tSU:DAT
tHD:DAT
tSU:STO tBUF
A = START CONDITION
B = MSB OF ADDRESS CLOCKED INTO SLAVE
C = LSB OF ADDRESS CLOCKED INTO SLAVE
D = R/W BIT CLOCKED INTO SLAVE
E = SLAVE PULLS SMBDATA LINE LOW
F = ACKNOWLEDGE BIT CLOCKED INTO MASTER
G = MSB OF DATA CLOCKED INTO SLAVE
H = LSB OF DATA CLOCKED INTO SLAVE
I = SLAVE PULLS SMBDATA LINE LOW
J = ACKNOWLEDGE CLOCKED INTO MASTER
K = ACKNOWLEDGE CLOCK PULSE
L = STOP CONDITION, DATA EXECUTED BY SLAVE
M = NEW START CONDITION
Figure 5. SMBus Write Timing Diagram
______________________________________________________________________________________ 15