MAX1153_10 Datasheet, PDF (15/30 Pages) Maxim Integrated Products – Stand-Alone, 10-Channel, 10-Bit System Monitors with Internal Temperature Sensor and VDD Monitor
Stand-Alone, 10-Channel, 10-Bit System Monitors
with Internal Temperature Sensor and VDD Monitor
Table 2. Command Description
COMMAND
WORD
DATA BYTES AFTER
COMMAND WORD
BYTES TO
DIN
BYTES FROM
DOUT
COMMAND DESCRIPTION
0000####
0
0
Manually Triggered Conversion
0001x x x x
0
3
Read Alarm Register
0010####
0
2
Read Current Data Register for Selected Channel
0011####
0
20
Read Current Data Register for All Channels
0100####
0
5
Read Configuration Register for Selected Channel
0101x x x x
0
5
Read Global Configuration Registers
0110x x x x
N/A
N/A
Reserved
0111x x x x
0
0
Reset
1000####
0
1001x x x x
0
0
Clear Alarm/Fault for Selected Channels
0
Clear Alarm/Fault for All Channels
1010####
2
1011x x x x
20
0
Write Current Data Register for Selected Channel
0
Write Current Data Registers for All Channels
1100####
5
0
Write Configuration Registers for Selected Channel
1101x x x x
5
1110x x x x
N/A
0
Write Global Configuration Registers
N/A
Reserved
1111x x x x
N/A
N/A
Reserved
#### = Channel address code, see Table 3.
xxxx = These bits are ignored for this command.
Table 3. Channel Address
ADDRESS IN COMMAND
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1010
1011
1100
1101
1110
1111
INPUT
Internal temperature
VDD
AIN0
AIN1
AIN2
AIN3
AIN4
AIN5
AIN6
AIN7
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Manually Triggered Conversion
(Command Code = 0000)
Before beginning a manual conversion, ensure the
scan mode bit in the setup register is zero, because a
logic 1 disables manual conversions. The address bits
in a Manually Triggered Conversion command select
the input channel for conversion (see Table 3). When
performing a differential conversion, use the even chan-
nel address (AIN0, AIN2, AIN4, AIN6); the command is
ignored if odd channel addresses (AIN1, AIN3, AIN5,
AIN7) are used for a differential conversion.
After issuing a Manually Triggered Conversion com-
mand, bring CS high to begin the conversion. To obtain
a correct conversion result, CS must remain high for a
period longer than the reference power-up time (if in
power-down mode) plus the conversion time for the
selected channel-configured conversion type (voltage
or temperature). The conversion’s result can then be
read at DOUT by issuing a Read Current Data Register
for Selected Channel command, addressing the con-
verted channel. See Table 3 for channel addresses.