English
Language : 

MAX34460 Datasheet, PDF (14/65 Pages) Maxim Integrated Products – PMBus 12-Channel Voltage Monitor and Sequencer
MAX34460
PMBus 12-Channel Voltage Monitor and Sequencer
Pin Description (continued)
PIN*
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
NAME
CONTROL
RST
ALARMCLR
SDA
SCL
VDD
REG18
FAULT2
MSCL
MSDA
PSEN8
PSEN9
PSEN10
PSEN11
ALARM0
ALARM1
ALERT
A1/PG
PG2
CONTROL2
RSG0
RSG1
PSEN0
PSEN1
PSEN2
PSEN3
PSEN4
PSEN5
TYPE**
AI
DIO
DI
DIO
DIO
Power
Power
DIO
DIO
DIO
DO
DO
DO
DO
DO
DO
DO
DIO
DO
DI
AI
AI
DO
DO
DO
DO
DO
DO
FUNCTION
Power-Supply Master On/Off Control for the Primary Sequence. Active low or active high
based on the ON_OFF_CONFIG command.
Active-Low Reset Input/Output. Contains an internal pullup.
Active-Low Alarm Clear Input with a Weak Pullup. Toggle low to clear the ALARM0/ALARM1
outputs. Leave open circuit or connect high if not used.
I2C/SMBus-Compatible Input/Open-Drain Output
I2C/SMBus-Compatible Clock Input/Open-Drain Output
Digital Supply Voltage. Bypass VDD to VSS with 0.1FF. Connect to VDDA.
Regulator for Digital Circuitry. Bypass to VSS with 1FF and 10nF (500mI maximum ESR). Do
not connect other circuitry to this pin.
Active-Low Fault Input/Output for the Secondary Sequence. See the Expanded Pin
Description section for more details.
Master I2C Clock Input/Open-Drain Output
Master I2C Data Input/Open-Drain Output
Power-Supply Enable Output 8. See the Expanded Pin Description section for more details.
Power-Supply Enable Output 9. See the Expanded Pin Description section for more details.
Power-Supply Enable Output 10. See the Expanded Pin Description section for more details.
Power-Supply Enable Output 11. See the Expanded Pin Description section for more details.
Active-Low Alarm Output 0. See the Expanded Pin Description section for more details.
Active-Low Alarm Output 1. See the Expanded Pin Description section for more details.
Active-Low, Open-Drain Alert Output
SMBus Address 1 Input/Power-Good Output for the Primary Sequence. This dual-function
pin is sampled on device power-up to determine the SMBus address. After device power-
up, this pin becomes an output that transitions high when all the enabled power supplies are
above their associated POWER_GOOD_ON thresholds. This pin is forced low immediately
when the CONTROL pin goes inactive or the OPERATION off command is received. This pin
contains a weak pullup during device reset.
Power Good for the Secondary Sequence
Power-Supply Master On/Off Control for the Secondary Sequence. Active low or active high
based on the ON_OFF_CONFIG command.
Remote-Sense Ground for RS0–RS3.
Remote-Sense Ground for RS4–RS11.
Power-Supply Enable Output 0. See the Expanded Pin Description section for more details.
Power-Supply Enable Output 1. See the Expanded Pin Description section for more details.
Power-Supply Enable Output 2. See the Expanded Pin Description section for more details.
Power-Supply Enable Output 3. See the Expanded Pin Description section for more details.
Power-Supply Enable Output 4. See the Expanded Pin Description section for more details.
Power-Supply Enable Output 5. See the Expanded Pin Description section for more details.
Maxim Integrated