English
Language : 

MAX3543 Datasheet, PDF (11/20 Pages) Maxim Integrated Products – Multiband Analog and Digital Television Tuner
Multiband Analog and
Digital Television Tuner
Register and Bit Descriptions
Table 4. R00: VCO Register—VCO and LO Divider Control (Address: 00h)
BIT NAME
BIT LOCATION
(0 = LSB)
VCO[1:0]
7:6
TYPICAL
SETTING
01
FUNCTION
VCO select. Selects one of three VCOs when VAS = 0, or selects the VCO starting
band when VASS = 0.
00 = Selects VCO1 (approximately 2200MHz to 2800MHz)
01 = Selects VCO2 (approximately 2800MHz to 3500MHz)
10 = Selects VCO3 (approximately 3500MHz to 4400MHz)
11 = VCO shutdown
VSUB[3:0]
5:2
0011
VCO sub-band select. Selects one of 16 possible VCO sub-bands when VAS = 0,
or selects the VCO starting sub-band when VASS = 0.
0000 = Selects SB0
…
1111 = Selects SB15
VDIV[1:0]
1:0
VCO divider ratio select.
00 = Sets VCO divider to 4 (use when fLO > 550MHz)
00
01 = Sets VCO divider to 8 (use when 275MHz < fLO < 550MHz)
10 = Sets VCO divider to 16 (use when 137.5MHz < fLO < 275MHz)
11 = Sets VCO divider to 32 (use when fLO < 137.5MHz)
Table 5. R01: NDIV INT Register—Integer Part of N-Divider (Address: 01h)
BIT NAME
BIT LOCATION
(0 = LSB)
TYPICAL
SETTING
FUNCTION
NINT[7:0]
7:0
0010
1011
Sets the PLL integer divide number (N)
Table 6. R02: NDIV FRAC2 Register—N-Divider Fractional Part [19:16] and R-Divider
(Address: 02h)
BIT
NAME
BIT LOCATION TYPICAL
(0 = LSB)
SETTING
FUNCTION
CPS
7
CP
6
RDIV[1:0]
5:4
F[19:16]
3:0
1
0
00
1110
Sets the charge-pump current-selection mode between automatic and manual.
Must set to 1 for proper operation.
For Maxim use only
Reference divider.
00 = /1
01 = /2
1X = Maxim use only
N-divider fractional part bits 19:16 (out of 19:0)
______________________________________________________________________________________   11