NOTES:
2. All voltages referenced to ground.
3. In battery backup mode, inputs must never be below ground or above VCCO.
4. Measured with outputs open.
5. All inputs within 0.3V of ground or VCCI.
6. Measured with a load as shown in Figure 3.
7. BW and RST are open drain outputs and, as such, cannot source current. External pull-up resistors
should be connected to these pins for proper operation. Both BW and RST can sink 10mA.
8. Chip Enable Outputs CEO1 – CEO4 can only sustain leakage current in the battery backup mode.
9. tCE maximum must be met to ensure data integrity on power down.
10. CEO1 through CEO4 will be held high for a time equal to tREC after VCCI crosses VCCTP on power-up.
11. The DS1323 is recognized by Underwriters Laboratories (UL) under file E99151.
DC TEST CONDITIONS
Outputs Open
All voltages are referenced to ground
OUTPUT LOAD Figure 3
AC TEST CONDITIONS
Output Load: See below
Input Pulse Levels: 0 – 3.0V
Timing Measurement Reference Levels
Input: 1.5V
Output: 1.5V
Input Pulse Rise and Fall Times: 5ns
*INCLUDING SCOPE AND JIG CAPACITANCE
11 of 14