FEATURES
ï§ Unique 1-Wire® Interface Requires Only One
Port Pin for Communication
ï§ Each Device has a Unique 64-Bit Serial Code
Stored in an On-Board ROM
ï§ Multidrop Capability Simplifies Distributed
Temperature Sensing Applications
ï§ Requires No External Components
ï§ Can Be Powered from Data Line. Power
Supply Range is 3.0V to 5.5V
ï§ Measures Temperatures from -55°C to
+125°C (-67°F to +257°F)
ï§ Â±0.5°C Accuracy from -10°C to +85°C
ï§ 9-Bit Thermometer Resolution
ï§ Converts Temperature in 750ms (max)
ï§ User-Definable Nonvolatile (NV) Alarm
Settings
ï§ Alarm Search Command Identifies and
Addresses Devices Whose Temperature is
Outside Programmed Limits (Temperature
Alarm Condition)
ï§ Applications Include Thermostatic Controls,
Industrial Systems, Consumer Products,
Thermometers, or FAunynTchteiromnaallly DSeinasgitirvaems
System
PIN CONFIGURATIONS
MAXIM
DS1820
123
N.C. 1
N.C. 2
VDD
3
DQ 4
8 N.C.
7 N.C.
6 N.C.
5 GND
SO (150 mils)
(DS18S20Z)
12 3
(BOTTOM VIEW)
TO-92
(DS18S20)
DESCRIPTION
The DS18S20 digital thermometer provides 9-bit Celsius temperature measurements and has an alarm
function with nonvolatile user-programmable upper and lower trigger points. The DS18S20
communicates over a 1-Wire bus that by definition requires only one data line (and ground) for
communication with a central microprocessor. It has an operating temperature range of â55°C to +125°C
and is accurate to ±0.5°C over the range of â10°C to +85°C. In addition, the DS18S20 can derive power
directly from the data line (âparasite powerâ), eliminating the need for an external power supply.
Each DS18S20 has a unique 64-bit serial code, which allows multiple DS18S20s to function on the same
1-Wire bus. Thus, it is simple to use one microprocessor to control many DS18S20s distributed over a
large area. Applications that can benefit from this feature include HVAC environmental controls,
temperature monitoring systems inside buildings, equipment, or machinery, and process monitoring and
coPnitnroClonsfyigsuteramtiosn. s appear at end of data sheet.
Functional Diagrams continued at end of data sheet.
1-WUiCreSiPs aisraegtriastdeeremdatrrkadoef mMaarxkimof IMntaexgimratIendtePgrraotdeudcPtsr,oIdnucc.ts, Inc.
For pricing, delivery, and ordering information, please contact Maxim Direct
at 1-888-629-4642, or visit Maximâs website at www.maximintegrated.com.
19-5474; Rev 8/10
|
▷ |