CFM05M Datasheet, PDF (2/2 Pages) Make-Ps – Single Output AC/DC Converter | |||
|
◁ |
www.make-ps.com
E-mail:info@make-ps.com
Specifications
CFM05M Series Derating Curve
INPUT SPECIFICATIONS:
Voltage â¦....â¦â¦â¦........â¦........................................... 85~264Vac
Frequency â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦.â¦â¦â¦â¦â¦..... 47 to 63Hz
Inrush Current â¦â¦â¦â¦â¦â¦â¦.â¦â¦â¦â¦.................... 40A max. @240Vac
Leakage Current â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦.â¦â¦ 100uA max.
OUTPUT SPECIFICATIONS:
Holdup Time â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦ 8mS typ. @115Vac
Short Circuit Protection â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦Continuous(Auto Recovery)
Over Voltage Protection â¦â¦â¦â¦â¦................... TVS Component to Clamp
Temperature Coefficient â¦â¦â¦â¦â¦â¦â¦â¦............................⦠±0.05%/â
GENERAL SPECIFICATIONS:
Isolation â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦..â¦â¦. Input to output = 5,656VDC
Operating Temperature ............................ 0â~ 85â (see derating curve)
Storage Temperature â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦...â¦.......â¦â¦........ -20~85â
Humidity ...................................................... 93% RH max. Non condensing
Cooling â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦..â¦â¦â¦â¦â¦â¦.. Natural Convection
Switching Frequency â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦.................. 60KHz Typical
MTBF â¦..â¦â¦ MIL-HDBK-217F, GB, at 25â/115VAC â¦â¦ 200K hrs min.
Altitude â¦â¦â¦â¦â¦â¦â¦â¦..â¦â¦â¦â¦â¦â¦...â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦.. 2000m
Dimensions â¦â¦.â¦â¦.. 2.165x1.378x0.827inches (55.00x35.00x21.00mm)
Weight â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦... 35g (0.08 Pounds)
CFM05M Series
All Dimensions are in inches(mm)
Tolerance:Inches:X.XXX±0.02
Millimeters:X.XX±0.5
100%
75%
50%
25%
20LFM(Natural Convection)
0%
0
10 20 30 40 50 60 70 80 90
Ambient Temperature(oC)
SAFETY AND EMC:
Emission and Immunity â¦â¦â¦â¦â¦....⦠EN55011 Class B, EN60601-1-2
EN61000-3-2, EN61000-3-3
Safety â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦â¦.. IEC60601-1, EN60601-1, UL60601-1
NOTE:
1. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for
Ripple & Noise measuring @20MHz BW.
2. Line regulation is measured from 100Vac to 240Vac with full load.
3. Load regulation is measured from 10% to 100% full load.
-Vo
ACN
ACL
+Vo
VR
Typical at 25ËC, nominal line and 75% load, unless otherwise Specified
2/2
|