English
Language : 

1600XA Datasheet, PDF (1/3 Pages) Make-Ps – Single, Dual, Triple Output DC/DC Converter
www.make-ps.com
FEATURES
E-mail:info@make-ps.com
1600XA series
Single, Dual, Triple Output
DC/DC Converter
• 6 sided Continuous Shielding
• Synchronization
• 10W/In3 Power Density
• Wide 2:1 Input Voltage Range
• Efficiency to 82%
• -55oC to +85oC Operation
• Meets MIL-STD-810 & MIL-STD-202
DESCRIPTIONS
The 1600XA series 16 watts high performance DC/DC
converters are cost effective solution to the high reliability
and performance requirements of power distribution
systems in applications ranging from high speed data
communications equipment to industrial robotic systems.
The 1600XA series operates from wide (2:1) input voltage
ranges of 9 to 18, 18 to 36 or 36 to 72VDC; providing single,
dual and triple output combinations of 5, 12, 15, ±5, ±12, ±15,
5/±12 and 5/±15 VDC. All models are packaged in compact,
low profile 2” X 2” X 0.4” metal cases.
INPUT CHARACTERISTICS
Min Typ Max Unit/Comments
Input Voltage Range
12 VDC Input Models 9 12 18 VDC
24 VDC Input Models 18 24 36 VDC
48 VDC Input Models 36 48 72 VDC
Remote On / OFF Control
Supply ON
3.5
VDC or Open Circuit
Supply OFF
0
0.8 VDC
Logic Referenced to Negative Input
Input Filter
Pi Filter
OUTPUT CHARACTERISTICS
GENERAL CHARACTERISTICS
Min Typ Max Unit/Comments
Output Voltage Accuracy
Single & Dual Outputs
±1.0 % 1
Triple Outputs - Primary
±1.0 % 1
- Auxiliaries
±6.0 % 1
Output Voltage Trim
±5 %
Voltage Balance:
Dual Outputs
±1.0 %; Equal Output Loads
Triple Outputs (Auxiliaries)
±1.0 %; Equal Output Loads
Minimum Load
10% Full Load
Line Regulation
Single & Dual Outputs
±0.5 % 2
Triple Outputs - Primary
±0.2 % 2
- Auxiliaries
±6.0 % 2
Load Regulation
Single Outputs
±0.2 % 3
Dual Outputs
±1.0 % 3 ; Equal Loads
Triple Outputs - Primary
±0.5 % 3
- Auxiliaries
±6.0 % 3 ; Equal Loads
Ripple/Noise
2 % of Vout
Short Circuit Protection
Continuous, Auto-
matic Recovery
Transient Recovery Time
200 μS to within1% error
band for 50% step
load change
Temperature Coefficient
±0.01 % per oC
Over Voltage Protection
See Model Selection Guide
Efficiency
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Acceleration
Shock
Vibration
Altitude
Switching Frequency
Unit/Comments
See Model Selection Guide
1400 VDC Min., 1 minute
Meets requirements of MIL-STD-202F, method
301
>109 Ohms; Meets requirements of MIL-STD-202F,
method 302, test condition B
140 pF
Per MIL-STD-810E, method 513.4, procedure II.
Operational test (centrifuge) 12g’s (manned aero-
space vehicles)
Per MIL-STD-801E, method 516.4, procedure I.
Functional shock 40g’s.
Per MIL-STD-810E, method 514.4, procedure I,
category 6 (equipment installed in helicopters).
Per MIL-STD-810E, method 500.3, procedure III
Rapid decompression, 40K ft.
100 kHz, Min.
1 = Output voltage at nominal line & FL
2 = % Output voltage measured from min. input line to maximum
3 = Output voltage measured from FL to 10% Load
>> 1