English
Language : 

1600 Datasheet, PDF (1/5 Pages) C&D Technologies – Dual and Quad Data-bus Isolators
www.make-ps.com
FEATURES
• 6 sided Continuous Shielding
• Synchronization
• 10W/In3 Power Density
• Wide 2:1 Input Voltage Range
• Efficiency to 82%
• UL 1950 Approved
• CSA 22.2-950 Approved
• VDE / EN 60950 Approved
DESCRIPTIONS
The 1600 series 16 watts high performance DC/DC
converters are cost effective solution to the high reliability
and performance requirements of power distribution
systems in applications ranging from high speed data
communications equipment to industrial robotic systems.
The 1600 series operates from wide (2:1) input voltage ranges
of 9 to 18, 18 to 36 or 36 to 72VDC; providing single, dual and
triple output combinations of 3.3, 5, 12, 15, ±5, ±12, ±15, 5/±12
and 5/±15 VDC. All models are packaged in compact, low
profile 2” X 2” X 0.4” metal cases.
OUTPUT CHARACTERISTICS
Min Typ Max Unit/Comments
Output Voltage Accuracy
Single & Dual Outputs
±1.0 % 1
Triple Outputs - Primary
±1.0 % 1
- Auxiliaries
±7.0 % 1
Output Voltage Trim
±10 %
Voltage Balance:
Dual Outputs
±1.0 %; Equal Output Loads
Triple Outputs (Auxiliaries)
±1.0 %; Equal Output Loads
Minimum Load
10% Full Load
Line Regulation
Single & Dual Outputs
±0.5 % 2
Triple Outputs - Primary
±0.5 % 2
- Auxiliaries
±5.0 % 2
Load Regulation
Single Outputs
±0.5 % 3
Dual Outputs
±1.0 % 3 ; Equal Loads
Triple Outputs - Primary
±0.5 % 3
- Auxiliaries
±5.0 % 3 ; Equal Loads
Ripple/Noise
5V Outputs
75 mV p-p, Nom.Line FL,
20Mhz B.W .using
1 μf bypass capacitor
12V and 15V Outputs
1 % of Vout
Short Circuit Protection
Continuous, Auto-
matic Recovery
Transient Recovery Time
200 μS to within1% error
band for 50% step
load change
Temperature Coefficient
±0.01 % per oC
Over Voltage Protection
See Model Selection Guide
E-mail:info@make-ps.com
1600 series
Single, Dual, Triple Output
DC/DC Converter
INPUT CHARACTERISTICS
Min Typ Max Unit/Comments
Input Voltage Range
12 VDC Input Models 9 12 18 VDC
24 VDC Input Models 18 24 36 VDC
48 VDC Input Models 36 48 72 VDC
Remote On / OFF Control
Supply ON
3.5
VDC or Open Circuit
Supply OFF
0
0.8 VDC
Logic Referenced to Negative Input
Reverse Polarity Input Current
12 Amp
Input Filter
Pi Filter
Input Fuse Rating
See Model Selection
Guide
GENERAL CHARACTERISTICS
Switching Frequency
Isolation Voltage
Isolation Resistance
Isolation Capacitance
MTBF (MIL-HBK-217F)
Min Typ Max Unit/Comments
100
kHz
1000
VDC, 1 minute
1000
Mohm, 500VDC
100
pF, 100kHz, 1Volt
705
Thousand Hours,
+25oC, Ground
Benign
1 = Output voltage at nominal line & FL
2 = % Output voltage measured from min. input line to maximum
3 = Output voltage measured from FL to 10% Load
>> B-144