1500WFR series
Single and Dual Output
DC/DC Converter
FEATURES
• 15W Continuous Output Power
• Compact 1” X 2” X 0.4” Case
• Industry Standard Pin-Out
• Up to 82% Efficiency
• -25oC to +71oC Operating Temperature Range
• 18.75W/In3 Power Density
• Low Cost
DESCRIPTIONS
The 1500WFR series is a family of low cost single and dual
output 15W DC/DC converters specifically designed for space-
critical applications. These models operate from wide (2:1)
input voltage ranges of 18 to 36 or 36 to 72 VDC; and provide
regulated outputs of 5, 12, 15, ±12 or ±15 VDC. Standard
features include 500 VDC input/output isolation, an internal
input filter, line/load regulation of ±1.0% and a minimum switch-
ing frequency of 190 kHz. All models are packaged in compact,
low profile 1” X 2” X 0.4” inch metal case. This miniature size
yields a power density as high as 18.75 watts/in3. Operation is
specified over the full operating temperature range of -25 oC to
+71 oC. Cooling is by free-air convection.
OUTPUT CHARACTERISTICS
Min Typ Max Unit/Comments
Output Voltage Accuracy
±1.0 %; Output voltage at
nominal line & FL
Output Voltage Balance
Dual Outputs
±1.0 %; Equal Output Loads
Minimum Load
10% of Full Load
Line Regulation
±0.2 % 1
Load Regulation
±1.0 % 2
Ripple/Noise
100 mV p-p, Nom.Line FL,
20Mhz B.W. using
1 μf bypass capacitor
Transient Response
500 μS to within 1% error
band for 25% step load
change
Temperature Coefficient
±0.02 % per oC
Short Circuit Protection
Current Limit,
Continuous
INPUT CHARACTERISTICS
Input Voltage Range
24 VDC Input Models
48 VDC Input Models
Input Filter
Min Typ Max Unit/Comments
18 24 36 VDC
36 48 72 VDC
Pi Networks
GENERAL CHARACTERISTICS
Switching Frequency
Isolation Voltage
Isolation Resistance
Min Typ Max Unit/Comments
190
kHz
500
VDC, 1 minute
1000
Mohm, 500VDC
1 = % Output voltage measured from min. input line to maximum at 100% Load.
2 = Output voltage measured from 25% Load to 100% Load, at Nominal Line.