SPECIFICATIONS
TRANSMITTER: FUNCTIONAL (CONT.)
Antenna
Encapsulated Horn
Wetted Surfaces
Environment
Operating Temperature
LCD
Storage Temperature
Humidity
Electromagnetic
Surge Protection
Shock Class
Vibration Class
Polypropylene, Tefzel® (optional)
-40° to +200° F @atmos (-40° to +93° C)
Vacuum to 200 psig @ +70° F (-1 to 13.8 bar)
Polypropylene or Tefzel (optional)
-40° to +175° F (-40° to +80° C)
-5° to +160° F (-20° to +70° C)
-50° to +175° F (-46° to +80° C)
0-99%, non-condensing
Meets CE Requirements: EN 50081-2, EN 50082-2
Meets CE Requirements: EN 61326 (1000 volts)
ANSI/ISA-S71.03 Class SA1
ANSI/ISA-S71.03 Class VC2
TRANSMITTER: PERFORMANCE
Reference Conditions
Linearity
Measured Error
Resolution
Repeatability
Response Time
Warm-up Time
Ambient Temp. Effect
Process Dielectric Effect
Maximum Rate of Change
Minimum Dielectric:
Reflection from ideal reflector at +70° F (+20° C)
±0.2 inch (5 mm) or 0.05% of tank height (whichever is greater)
±0.2 inch (5 mm) or 0.05% of tank height (whichever is greater)
(Performance will degrade slightly within 60" (1.5 m) of antenna)
0.1 inch (2.5 mm)
< 0.1 inch (2.5 mm) or 0.025% of tank height
< 1 second
30 seconds
±.02% of span per degree C, tank heights > 100" (2.54 m)
< 0.3 inch within selected range
180 inches (450 cm)/minute
1.7
ANTENNA: FUNCTIONAL
Encapsulated
Horn Antenna
Polypropylene
Tefzel®
Process Connection 2" NPT/BSP hygienic flanges
Maximum Process
Temperature
Maximum Process
Pressure
Minimum Dielectric
(application dependent)
-40° to +200° F @ atmos
(-40° to +93° C @ atmos)
Vacuum to 200 psig @ +70° F
(-1 to 13.8 bar @ +20° C)
1.7
ANTENNA: RATINGS
PRESSURE/TEMPERATUREŒ
300 (21)
200 (14)
100 (7)
0
-50 0 50 100 150 200 250 300
(-46) (-18) (10) (38) (66) (93) (121) (149)
Temperature ° F (° C)
ΠMaximum Pressure ratings for CRN are derated
to 130 psig (-1 to +9 bar) @ +70° F (+20° C)
9