English
Language : 

801-2031-A40 Datasheet, PDF (4/8 Pages) Magnetrol International, Inc. – Kotron® Model 801 RF Capacitance Transmitter for Level/Flow/Volume
SPECIFICATIONS
Supply voltage
Output:
Analog
Digital
Range
Accuracy
Repeatability
Linearity
Data:
Entry
Indication
Relays 4 SPDT:
AC
DC
Set point range
Differential range
Time delay
Power consumption
Humidity
Response time
Ambient temperature (electronics):
Without heater and thermostat
With heater and thermostat
Temperature coefficient of set point
Maximum remote mount distance:
Standard
Intrinsically safe
120 VAC, 50/60 Hz (+10 / -15%)
240 VAC, 50/60 Hz (+10 / -15%)
24 VDC (±10%)
4–20 mA (isolated), reversible 1000 ohms max. loop resistance
RS-232
5 pF minimum / 50,000 pF maximum
Better than 1.0% of span
±0.1%
±0.5%
Full numeric keypad
16-character alphanumeric LCD display
10 amp @ 120/240 VAC resistive
10 amp @ 30 VDC resistive, 0.5 amp @ 125 VDC resistive
0–50,000 pF
0.50 pF minimum / 50,000 pF maximum
0–120 seconds level rising, falling, both
15 Watts maximum
65 Watts maximum with heater
99% non-condensing (electronics)
0.5 to approximately 2 seconds, depending upon probe
capacitance and damping value
-4° to +160° F (-20° to +70° C)
-40° to +160° F (-40° to +70° C)
±0.01% / degree F (±0.018% / degree C)
2500 feet (760 meters)
800 feet (240 meters)