English
Language : 

300-R010-45L Datasheet, PDF (4/12 Pages) Magnetrol International, Inc. – Echotel® Model 300/301 Ultrasonic Non-Contact Transmitter For Level, Volume, and Open Channel Flow
AGENCY APPROVALS
AGENCY
FM
MODEL
300-RXXX-45X
301-RXXX-400 with
384-XKXX-0XX
PROTECTION METHOD
Indoors & Outdoors
Hazardous locations
CSA
300-RXXX-45X
301-RXXX-400 with
384-XKXX-0XX
300-RXXX-45X
301-RXXX-400 with
384-XK0X-0XX
384-XK1X-0XX
and
384-XKYX-0XX
Non-hazardous
Hazardous locations
Hazardous locations
AREA CLASSIFICATION
NEMA Type 4X & IP 65
Class I, Div. 1; Groups B, C & D
Class II, Div. 1; Groups E, F & G
Class III
TYPE 4X enclosure
Class I, Div. 1; Groups B, C & D
Class II, Div. 1; Groups E, F & G
Class III
Class I, Div. 1; Groups C & D
Class II, Div. 1; Groups E, F & G
Class III
These units have been tested to EN 50081-2
and EN 50082-2 and are in compliance with
the EMC Directive 89/336/EEC.
DIMENSIONAL SPECIFICATIONS
INCHES (MM)
3.87 (98)
Rotation
clearance
5.93 (151)
1" NPT
(plugged)
8.46
(215)
12.25
1" NPT (311)
2" NPT
Process
Connection
3.00 (76) or 10.00 (254)
Insertion Length
2.12 (54) Insertion Diameter
Model 300 Integral Mount
3.87 (98)
Rotation
clearance
5.93
(151)
10.68
(271)
8.46
(215)
2 Holes
.38 (10) Dia.
2.00
(51)
1" NPT
2.37
(60)
1" NPT
3.75
3.00
(95)
(76)
3/4" NPT
Plug
3.50
(89)
Model 301 Remote Mount with Bracket
4