English
Language : 

TD2-7D00-074 Datasheet, PDF (3/4 Pages) Magnetrol International, Inc. – Hygienic Thermatel® Thermal Dispersion Flow & Level Switch
DIMENSIONAL SPECIFICATIONS INCHES (MM)
Model TD2 with Hygienic Housing & Tri-Clamp® Connection
5.24
(133)
5.75
(146)
1.05 (26)
Typical
Insertion
length
Æ .875
(22) Dia.
MODEL NUMBER
STANDARD PROBE
MODEL
TE Probe length in inches
TM Probe length in centimeters
TIP STYLE
A Spherical tip
B Spherical tip – with 4" heat extension
max. +250° F (+121° C)/max. 600 psi (41 bar)
max. +400° F (+204° C)/max. 600 psi (41 bar)
MATERIAL OF CONSTRUCTION
A 316/316L stainless steel
HYGIENIC CONNECTIONS
3T 1" and 11⁄2" Tri-Clamp®
4T 2"
Tri-Clamp
VV DN65
Varivent®
Contact Magnetrol for other hygienic fittings including Neumo, G1A, and DIN 11.851.
INSERTION LENGTH
002 2" minimum with Tri-Clamp connection
003 2" minimum with Varivent connection
in 1" increments to length of 130 inches
005 Minimum length 50 mm with Tri-Clamp connection
006 Minimum length 60 mm with Varivent connection
Extended lengths in 10 mm increments to length 3300 mm
Examples: 50 mm = code 005, 3300 mm = code 330
A
0
3