English
Language : 

804-R010-230 Datasheet, PDF (3/8 Pages) Magnetrol International, Inc. – Kotron® Sentinel Model 804 RF Level Transmitter
AGENCY APPROVALS
Agency
FM
Approved Model
804-XXXX-23X
804-XXXX-33X
Insulated rigid probes only
Protection Method
Explosion proof
804-XXXX-53X
804-XXXX-63X
Explosion proof
with intrinsically safe
probe circuit
CSA
804-XXXX-23X
804-XXXX-33X
Insulated rigid probes only
804-XXXX-53X
804-XXXX-63X
Explosion proof
Explosion proof Œ
with intrinsically safe
probe circuit
ΠFor Class II, Groups E & F insulated probes must be used
Area Classification
Class I Div. 1, Groups B, C & D
Class II, Div. 1, Groups E, F, & G
Class III
NEMA 4X, IP65
Integral units
Class I Div. 1, Groups B, C & D
Class II, Div. 1, Groups E, F, & G
Class III
NEMA 4X, IP65
Electronics
Class I Div. 1, Groups B, C & D
Class II, Div. 1, Groups E, F, & G
Class III
NEMA 4X, IP65
Remote probe
Class I Div. 1, Groups A, B, C & D
Class II, Div. 1, Groups E, F, & G
Class III, NEMA 4X, IP65
Class I Div. 1, Groups C & D
Class II, Div. 1, Groups E, F, & G
Class III
TYPE 4X
Integral units with IS probe circuit
Class I Div. 1, Groups B, C & D
Class II, Div. 1, Groups E, F, & G Œ
Class III
TYPE 4X
Electronics
Class I Div. 1, Groups B, C & D
Class II, Div. 1, Groups E, F, & G Œ
Class III
TYPE 4X
Remote probe
Class I Div. 1, Groups A, B, C & D
Class II, Div. 1, Groups E, F, & G Œ
Class III
TYPE 4X
These units have been tested to EN 50081-2
and EN 50082-2 and are in compliance with
the EMC Directive 89/336/EEC.