3.5 Specifications
3.5.1 Functional
System Design
Measurement Principle
Input
Measured Variable
Zero and Span
Output
Type
Analog
Range
Analog
Digital
Resolution
Analog
Digital
Loop Resistance
Diagnostic Alarm Â
Damping
User Interface
Keypad
Indication
Digital Communication Â
Power (Measured at instrument terminals)
General Purpose/Intrinsically Safe (FM/CSA)
General Purpose/Intrinsically Safe (ATEX)
Explosion Proof FM/CSA
Housing
Material
Cable Entry
Model 704
Guided time-of-flight via time domain reflectometry
Level, determined by the time-of-flight of a guided radar
pulse from transmitter to product surface and back
6 to 192 inches (15 cm to 488 cm)
4 to 20 mA with optional HART digital signal
3.8 to 20.5 mA useable
0 to 192 inches (0 to 488 cm)
0.01 mA
0.1" or 0.1 cm
GP/IS/XP- 550 ⦠@ 24 VDC (20.5 mA)
Adjustable 3.6 mA, 22 mA, HOLD
0-10 seconds
3-button menu-driven data entry
2-line x 8-character display
HART Version 5.x compatible
12 to 28.6 VDC
12 to 28.6 VDC
12 to 28.6 VDC
Pi = 0.67W, Ii = 94 mA
Aluminum A356T6 (< 0.2% copper)
3â4" NPT, M20
 3.6 mA diagnostic alarm only valid without HART or display option.
 HART communicator Magnetrol P/N 89-5213-XXX sold separately.
1200
20.5 mA
1000
800
â¦
600
550
400
200
0
0
12
10
24 VDC
20
30
40 VDC
GENERAL PURPOSE (GP)
INTRINSICALLY SAFE (IS)
EXPLOSION PROOF (XP)
23
57-603 Horizon Guided Wave Radar Transmitter
|
▷ |