English
Language : 

811-1005-E01 Datasheet, PDF (21/28 Pages) Magnetrol International, Inc. – Kotron® Model 811 RF Point Level Sensor
2.4 Agency Approvals
Agency
FM
CSA
Approved Model Protection Method
811-1X05-E0X
Explosion Proof
811-1X06-E0X
with probe models:
041-5XXX-XXX and
8XX-XXX-XXX
811-1X06-E0X
Intrinsically Safe
(Remote)
with probe models:
041-5XXX-XXX and
8XX-XXX-XXX
811-1X05-E0X
Explosion Proof
811-1X06-E0X
with probe models:
041-5XXX-XXX and
8XX-XXX-XXX
811-1X06-E0X
Intrinsically Safe
(Remote)
with probe models:
041-5XXX-XXX and
8XX-XXX-XXX
Area Classification
Explosion proof with intrinsically safe probe circuit
Class I, Div. 1, Groups C & D
Class II, Div. 1, Groups E, F, & G
NEMA 4X
Remote probe:
Class I, Groups A, B, C, & D
Class II, Div. 1, Groups E, F, & G
Class III,
NEMA 4X
Explosion proof with intrinsically safe probe circuit
Class I, Div. 1, Groups C & D
Class II, Div. 1, Groups E, F, & G
(Bare probes not approved for Groups E & F)
TYPE 4X
Remote probe:
Class I, Div. 1, Groups A, B, C, & D
Class II, Div. 1, Groups E, F, & G
(Bare probes are not approved for Groups E & F)
Class III
TYPE 4X
These units have been tested to EN 50081-2
and EN 50082-2 and are in compliance with
the EMC Directive 89/336/EEC.
50-608 Kotron Model 811 RF Point Level Sensor
18