961-20A0-011 Datasheet, PDF (10/12 Pages) Magnetrol International, Inc. – Echotel® Model 961/962 Ultrasonic Level Switches | |||
|
◁ |
MODEL NUMBER
962 DUAL POINT TRANSDUCER
TRANSDUCER UNIT OF LENGTH
A English (length in inches)
M Metric (length in centimeters)
MATERIALS OF CONSTRUCTION
A 316/316L stainless steel
K 316/316L stainless steel, ASME B31.1 &B31.3 construction
P CPVC (use only with Process Connection codes 11, 23, 33, 43, BA, CA, DA)
PROCESS CONNECTIONS
THREADED CONNECTIONS
11 3â4" NPT
21 1" NPT
22 1" BSP (G1)
ANSI RAISED FACE FLANGES
23 1" 150# ANSI RF flange
24 1" 300# ANSI RF flange
25 1" 600# ANSI RF flange
33 11â2" 150# ANSI RF flange
34 11â2" 300# ANSI RF flange
35 11â2" 600# ANSI RF flange
43 2" 150# ANSI RF flange
44 2" 300# ANSI RF flange
45 2" 600# ANSI RF flange
EN/DIN FLANGES
BA DN 25 PN 16 EN 1092-1 Type A
BB DN 25 PN 25/40 EN 1092-1 Type A
BC DN 25 PN 63/100 EN 1092-1 Type B2
CA DN 40 PN 16 EN 1092-1 Type A
CB DN 40 PN 25/40 EN 1092-1 Type A
CC DN 40 PN 63/100 EN 1092-1 Type B2
DA DN 50 PN 16 EN 1092-1 Type A
DB DN 50 PN 25/40 EN 1092-1 Type A
DD DN 50 PN 63 EN 1092-1 Type B2
DE DN 50 PN 100 EN 1092-1 Type B2
9
2
10
Important:
Use the âAâ dimension as
the actuation length code.
The âBâ dimension must also
be specified in quote/order.
Example:
For a 962 with an âAâ
dimension of 18" and a âBâ
dimension of 7", specify
actuation length code 018.
Actuation
length B
min. 2" (5 cm)
Actuation
length A
Minimum distance
between actuation points
A and B is 3" (8 cm)
Maximum distance
between actuation points
A and B is 125" (318 cm)
âAâ DIMENSION ACTUATION LENGTH* (units specified in second digit)
5" to 130" in 1" increments
5" minimum for NPT process connections
6" minimum for BSP, and flanged process connections
Example: 5 inches = 005
13 cm to 330 cm in 1 cm increments
13 cm minimum for NPT process connections
15 cm minimum for BSP, and flanged process connections
Example: 13 centimeters = 013
* For lengths longer than 130" (330 cm), contact the factory
A
|
▷ |