822-1000-C00 Datasheet, PDF (1/8 Pages) Magnetrol International, Inc. – Kotron® Sentinel Models 822, 832 and 842 RF Point Level Switches | |||
|
Kotron® Sentinel
Models 822, 832 and 842
RF Point Level Switches
DESCRIPTION
The Sentinel is a powerful multi-point level switch. The
microprocessor-based circuitry has non-volatile memory,
to protect against data loss. Powerful diagnostics check
all major aspects of the system while MagneCal⢠offers
the user the advantage that one small level change is
needed to calibrate.
FEATURES
⢠Optional intrinsically safe probe circuitry (with
on-board barriers) allows safe use, even with bare
probes in hazardous media
⢠Intrinsically safe remote mount models up to
800 feet (240 meters) of cable
⢠Integral or standard remote mount up to
2500 feet (760 meters) for application flexibility
⢠Two to four DPDT relays yield wide application
flexibility for most alarm and control operation
⢠Relays 2 and 3, Series 832/842 models, may be used
for lead/lag pump sequencing
⢠Time delay eliminates relay chatter due to turbulence.
⢠Usable with all Kotron probes for excellent application
flexibility
⢠3-button/4-digit LED data entry of all parameters
⢠One small level change (2% of span) needed for initial
calibration in most cases
⢠Powerful self-diagnostics check the system, minimizing
the need for routine maintenance checks
⢠Diagnostics check the integrity of the probe
⢠One relay may be dedicated as a diagnostic alarm
APPLICATIONS
⢠Hydrocarbons and solvents
⢠Corrosives
⢠High temperature/pressure liquids
⢠Multi-point alarm/control
⢠Pump control
⢠Lead/Lag pump control
⢠Process temperatures up to +1000° F
⢠Process pressures up to 5000 psig
|
▷ |