English
Language : 

DS11-1Y Datasheet, PDF (4/4 Pages) Tyco Electronics – DC solid state relay for loads up to 2A @ 60Vdc
DS11 Series High Performance Solid State Relays
DC solid state relay for loads up to 2A @ 60Vdc (Continued)
Figure 7 - Temperature Derating Curve
2.0
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0
-50 -40 -20 0 20 40 60 80 100 120
Ambient Temperature (°C)
Figure 8 - Maximum Surge Current Without Tripping
7.0
-55°C
6.0
5.0
+25°C
4.0
3.0
2.0 +85°C
1.0
0.01
0.1
1
10
Time (seconds)
Figure 9 - Outline Dimensions
.140
(3.55)
.530 MAX
(13.46)
.200
(5.08)
.890 MAX.
(22.60) .600
.500
(12.70)
(15.24)
.273 ±.020
(6.93 ± .50)
.020 MAX.
(.50)
.850 REF.
(21.59)
.490 REF.
(12.44)
TOP MARKING
ORIENT AS
SHOWN
.110
(2.79)
.190 MAX.
(4.82)
TOLERANCE:
.300
(7.62)
.017 +.002, –.001 DIA.
(.43 + .05, –.02)
6 PLS.
± 0.010 (0.25mm) FOR 2 PLACE DECIMALS,
± 0.005 (0.13mm) FOR 3 PLACE DECIMALS.
UNLESS OTHERWISE SPECIFIED
DATE CODE
HERE
Notes
1.2 terminal input configuration is compatible with CMOS or open collector TTL (with pull-up resistor). For Vcc levels above 6Vdc, a series limiting resistor is
required. See Fig. 2 for resistor value. Use standard resistor value equal to or less than value from the curve.
2.Input transitions to be ≤ 1ms duration, and input direct drive should be “bounceless contact” type.
3. Vcc = 5Vdc for all tests unless otherwise specified.
4.All DS11 Series relays may drive loads connected to either positive or negative referenced power supply lines. Reversing polarity of output may cause permanent
damage. Inductive loads must be diode suppressed.
5.Transient blocking voltage and electrical system spike tests are performed per MIL-STD-704 (28VDC systems).
6.To determine the maximum on-resistance at any given junction temperature, multiply on-resistance at 25°C (0.15 ohm) by normalized on-resistance factor from
curve (Fig. 6).
7.Overload testing per MIL-R-28750 is constrained to the limits imposed by the short circuit protection requirements of this specification and DSCC drawing 88062.
Load circuit series inductance for “load shorted” mode of operation to be limited to 50mH max. Maximum repetition rate into a shorted load should not exceed 10
Hz.
8.Proper operation of the status feedback requires a status pull-up resistor. See Fig. 5 for status resistor value.
DS11-TBD–PDF–KRG–1-04
4
www.tycoelectronics.com
Dimensions are in inches and
millimeters unless otherwise
specified. Values in brackets
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA: 1-800-522-6752
Canada: 1-905-470-4425
Mexico: 01-800-733-8926
C. America: 52-55-5-729-0425
South America: 55-11-3611-1514
Hong Kong: 852-2735-1628
Japan: 81-44-844-8013
UK: 44-141-810-8967