English
Language : 

408-10002 Datasheet, PDF (4/5 Pages) Tyco Electronics – Cumulative Trauma Disorders can result from the prolonged use ofmanually powered hand tools.
SDE- SA Hand Tool Assembly 1752938- 1
408- 10002
4. Remove all lubrication and accumulated film
from the dies by immersing the dies in a suitable
commercial degreaser.
Adjustment
Screw
Ratchet Adjustment Wheel
Figure 4
8.2. Inspection
1. Close the tool handles until the ratchet releases,
and then allow them to quickly open freely. If they
do not open quickly and fully, the spring is
defective. See Section 9, REPLACEMENT.
2. Inspect the crimping surfaces of the dies for
flattened, chipped, worn, or cracked areas. If
damage is evident, the dies must be replaced.
Refer to Section 9, REPLACEMENT.
8. MAINTENANCE AND INSPECTION
8.1. Daily Maintenance
1. Remove dust, moisture, and other contaminants
with a clean, soft brush, or a clean, soft, lint--free
cloth. DO NOT use any objects that could damage
the dies or tool.
2. Make sure that the proper die retaining screws
are properly secured.
3. When the tool is not in use, keep the handles
closed to prevent objects from becoming lodged in
the dies. Store the tool in a clean, dry area.
9. REPLACEMENT
Order replacements through your representative, or
call 1--800--526--5142, or send a facsimile of your
purchase order to 717--986--7605, or write to:
CUSTOMER SERVICE (038--035)
TYCO ELECTRONICS CORPORATION
PO BOX 3608
HARRISBURG PA 17105--3608
10. REVISION SUMMARY
S Updated document to corporate requirements
S Changed SDE PEW--12 to SDE--SA
S Added back page showing tooling compatible
with Die Assembly 1752938--2
4 of 5
Tyco Electronics Corporation