English
Language : 

V23201 Datasheet, PDF (3/5 Pages) Tyco Electronics – Power Relay PK2 (THT – THR) Single Relays PCB Relays
PCB Relays
Single Relays
Power Relay PK2 (THT – THR)
Catalog 1308028-2
Revised 3-2008
Contact Data
Typical areas of application
Contact configuration
Circuit Symbol
(see also Pin assignment)
Resistive/inductive/capacitive load
1 Make contact/
1 Form A
5 (+)
4 (-)
Rated voltage
Rated current 1)
at
Limiting continuous current 1)
23°C
85°C
105°C
Contact material
Max. switching voltage/power
Max. switching current 2)
On
Off
Min. recommended load 3)
Voltage drop at 10 A (initial)
NO contact
Mechanical endurance (without load)
Examples of electrical endurance
at cyclic temperature –40/+23/+85°C
and 13.5 V; 120 ms - on/4880 ms - off
Max. switching rate at nominal load
12 V
33 A
40 A
33 A
22 A
Silver based
See load limit curve
200 A
40 A
1 A at 5 V
Typ. 30 mV, 300 mV max.
> 2 x 106 operations
Inductive load: > 1 x 105 operations, 60 A on/35 A 0ff, L = 0.5 mH
Resistive load: > 1 x 105 operations, 40 A on/40 A 0ff
Capacitive load : > 1 x 105 operations, 200 A on/20 A 0ff
6 operations per minute (0.1 Hz)
1) Measured on 70 mm x 70 mm x 1.5 mm epoxy PCB FR4 with 52 cm2 (double layer 140 μm thick) copper area.
2) The values apply to a resistive or inductive load with suitable spark suppression and at maximum 13.5 V for 12 V load voltages.
3) See chapter Diagnostics of Relays in our Application Notes page 31 or consult the internet at http://relays.tycoelectronics.com/appnotes/
Load Limit Curve
201C_LLC3
Load limit curve ^= safe shutdown, no stationary
arc/make contact
136
All specifications subject to change. Consult Tyco Electronics for latest specifications.