V23130 Datasheet, PDF (3/4 Pages) Tyco Electronics – Battery Disconnect Switch BDS-A High Current Solutions
High Current Solutions
High Current Devices
Battery Disconnect Switch BDS-A
Contact Data for cable size ≥ 50 mm2
Contact configuration
Circuit symbol 1), 2)
Catalog 1308028-2
Revised 3-2008
Form X
Rated voltage
12 V
Rated current
190 A
Limiting continuous current
23°C
260 A
85°C
190 A
125°C
88 A
Contact material
Silver based
Load current
From terminal B to A
Carrying capability: 1000 A 1 s on, 9 s off, 23°C, 50 mm2
50.000 operations 3)
Carry starter current: 1500 A-0.2 s/600 A-5 s on, 60 s off, 23°C, 50 mm2
50.000 operations 3)
Voltage drop at 100 A (initial, after 1 min)
< 40 mV
Electrical endurance: 180 A 0.1 mH 1.5 s on, 5 s off, (–40/25/120)°C/2 h each, 35 mm2
13.000 operations
Electrical endurance: 100 A 0.1 mH 1.5 s on, 5 s off, (–40/25/120)°C/2 h each, 35 mm2
50.000 operations
Electrical endurance: 150 A 0.1 mH 0.5 s on, 5 s off, (–40/25/120)°C/2 h each, 35 mm2
–
Electrical endurance: 100 A 0.1 mH 0.5 s on, 5 s off, (–40/25/120)°C/2 h each, 35 mm2
–
Switching capability: 1500 A 0.5 s on, 10 min off, 23°C, 50 mm2 resistive load
5 operations 3)
Max. temperature at load terminals
140°C
Mechanical shock, half sine, 6 ms, 6 directions (OFF→ON)
40 g 3)
1) Delivery status “ex works”.
2) Refer to Latching Relay in the “Glossary”.
3) Values are influenced by system temperature and load current. For further details please consult our Technical Application Engineers.
24 V
–
–
25.000 operations
70.000 operations
Circuit Diagram
X2C2D
1 Double make contact/1 Form X
with 2 Coils and 2 Diodes
130C_PA_3
Coil Data
Available for nominal voltages
Must operate voltage at 20°C (ON→OFF→ON) 1)
Non operate voltage at 20°C 1)
Test voltage winding/contact, contact-contact 1)
Ambient temperature range
Coil excitation pulse length recommended/maximum
Switching time at 14 V
Noise level 2)
12 V
24 V
06 V
12 V
02 V
04 V
500 VACrms
–40 to +120°C
50 ms/100 ms
ON-OFF typ. 5 ms/OFF-ON typ. 5 ms
Typ. 86 dB (A)
1) Values are influenced by system temperature and load current. For further details please consult our Technical Application Engineers.
2) Equivalent average sound pressure level leq, switch cycled with 1 Hz, microphone distance 10 cm, measuring time 15 s.
All specifications subject to change. Consult Tyco Electronics for latest specifications.
201