English
Language : 

408-9085 Datasheet, PDF (3/5 Pages) Tyco Electronics – Reasons for reissue of this instruction sheet are provided in Section 8, REVISION SUMMARY.
Terminating Head 58062- 1
408- 9085
AMPMODU MT
Receptacle Connector
Correct
Termination Inspection
Acceptable
0.51
[.020]
Min
Arms of Insulation Support
Barrel Completely Closed
Section A- A
Top of Wire
Barrel Slot
Arms of Insulation Support
Barrel Partially Closed
A
A
Top of Wire Conductor Below
Top of Wire Barrel Slot
Incorrect
Damaged Housing— Wire Was Not Inserted
Connector Was Too Deep Enough During
Tight or Too Loose in
Termination
Head During Termination
Wire Was Inserted With
Too Much Force During
Termination
Wire Was Not Inserted
Straight Before
Termination
Wire Was Not Fully
Inserted Before
Termination
Figure 4
B. Manual and Electric Power Units
1. Remove the head from the power unit according
to the instructions packaged with the power unit.
Make sure to observe any cautions and dangers.
2. Turn the adjuster one--sixth of a revolution
clockwise if the wire is too deep in the contact, and
counterclockwise if the wire is not deep enough in
the contact. Refer to Figure 5. This will decrease or
increase the wire insertion depth by approximately
0.20 [.008].
3. Install the head onto the power unit according to
the instructions packaged with the power unit.
Make sure to observe any cautions and dangers.
Wire Insertion Depth Adjustment
Turn CLOCKWISE
To Decrease
Wire Insertion Depth
Turn COUNTERCLOCKWISE
To Increase
Wire Insertion Depth
Figure 5
Adjuster
Rev B
Tyco Electronics Corporation
3 of 5