English
Language : 

412-18745 Datasheet, PDF (21/26 Pages) Tyco Electronics – The operating manual must be constantly within reach of the tool.
6-744011-7
41421-21-81784754-51 Rev.B
Figure 3
Used with
cylinder
Usable oil
capacity
Model
number
Pressure rating
Oil displacement
per stroke
1. stage 2. stage 1. stage 2. stage
Max.
handle
effort
Piston
stroke
Weight
Single acting
492cm³
[30in³]
523199-2
(yellow)
523199-3
(blue)
700bar
15bar [10.000psi] 11,26cm³ 2,47cm³
[220psi] 580bar [.687in³] [.151in³]
[8286psi]
Table 1
42kg
25,4mm 7,0kg
[93lbs] [1,00Zoll] [15,4lbs]
WARNING: These pumps are operated with a non vented reservoir. If the reservoir is subjected to high
pressure, the casing may rupture, causing personal injury and/or equipment damage. NEVER attempt to
return more oil to the reservoir than it is capable of holding.
NOTE: The pumps are equipped with a clicker valve which opens as soon as the set pressure is reached.
During operation this valve clearly indicates that the working pressure of 700 bars respective 580 bars is
reached.
6 Installation
6.1 Connecting the pump
1. Insert the male coupling of the hydraulic hose into the female coupling on the pump. Tighten the cap
nut on the pump (see figure 4, 5 and 6).
Page 21 / 26
ECOC: EGC0 ; LOC: AI