English
Language : 

T9C Datasheet, PDF (2/3 Pages) Tyco Electronics – Power Relay T9C AC coil
General Purpose Relays
Power Relay T9C AC coil (Continued)
SCHRACK
Insulation
Dielectric strength coil-contact circuit
open contact circuit
Clearance / creepage coil-contact circuit
Tracking index of relay base
Insulation to IEC 61810-1
Type of insulation coil-contact circuit
open contact circuit
Rated insulation voltage
Pollution degree
Rated voltage system
Overvoltage category
2500 Vrms
1500 Vrms
W 2.5 / 4 mm; W 3.1 / 6.3 mm (UL508)
175
basic
micro disconnection
250 V
2
277 V
II
Other data
Mechanical endurance
typ. 5x106 cycles
Material
RoHS - Directive 2002/95/EC
compliant
Environment
Ambient temperature range
-40...+70°C
Vibration resistance (function) NO / NC contact 1.5 mm, 10...55 Hz
Shock resistance (function) NO / NC contact
10 g for 11 ms
Shock resistance (destruction)
100 g for 6 ms
Category of protection
RT I - dust protected
Processing
Relay weight
33 g
Packaging unit
250 pcs
Terminal assignment
S0261-AI
S0261-AJ
Dimensions
S0291-A
Datasheet Rev. IJ1
Issued 2009/10
www.tycoelectronics.com
www.schrackrelays.com
2
Dimensions are in mm unless Product specification
processing information only in the ‘Schrack’ section.
otherwise specified and are
according to IEC 61810-1.
to be used together with the
shown for reference purposes Product data, technical para- 'Definitions' section in the cat- Specifications subject to
only.
meters, test conditions and
alogue or at schrackrelays.com change.