GaAs SPD Switch, DC - 3.0 GHz
Absolute Maximum Ratings1
Parameter
Max. Input Power (0.5 - 3.0 GHz)
3 V Control
5 V Control
Operating Voltage
Absolute Maximum
+30 dBm
+33 dBm
+8.5 Volts
Operating Temperature
-40°C to +85°C
Storage Temperature
-65°C to +150°C
1. Exceeding any one or combination of these limits may cause
permanent damage.
Truth Table
Mode
(Control)
Positive1
Negative2
V1
0±0.2V
+2.5 to +8V
0±0.2V
-2.5V to -8V
V2
+2.5 to +8V
0±0.2V
-2.5V to -8V
0±0.2V
RFC - RF1 RFC - RF2
On
Off
Off
On
Off
On
On
Off
1. External DC blocking capacitors are required on all RF ports.
39pF capacitors used for positive control voltage.
2. If negative control is used, DC blocking capacitors are not required
on RF Ports.
PIN Configuration
PIN No.
Function
1
RF1
2
GND
3
RF2
4
V2
5
RFC
6
V1
Description
RF in/out
RF Ground
RF in/out
V Control 2
RF COMMON
V Control 1
Functional Schematic
Positive Control Voltage
PIN 1
RF1
39pF
GND
RF2
39pF
Functional Schematic
Negative Control Voltage
PIN 1
RF1
GND
RF2
SW-437
V1
RFC
39pF
V2
V1
RFC
V2
Handling Procedures
The following precautions should be observed to avoid damage:
Static Sensitivity
Gallium Arsenide Integrated Circuits are ESD sensitive and can
be damaged by static electricity. Proper ESD techniques should
be used when handling these devices.
M/A-COM Division of AMP Incorporated 3 North America: Tel. (800) 366-2266, Fax (800) 618-8883 3 Asia/Pacific: Tel.+81 44 844 8296, Fax +81 44 844 8298
3 Europe: Tel. +44 (1344) 869 595, Fax+44 (1344) 300 020
www.macom.com
AMP and Connecting at a Higher Level are trademarks.
Specifications subject to change without notice.
V2.00