English
Language : 

PTF_09 Datasheet, PDF (2/3 Pages) Tyco Electronics – Miniature Power Relay PTF
General Purpose Relays
Miniature Power Relay PTF (Continued)
SCHRACK
Coil versions, AC-coil 50 / 60 Hz
Coil
Rated
Operate Release
Coil
Rated coil
code
LED
voltage
voltage
voltage resistance
power
50 / 60 Hz 50 / 60 Hz
50 / 60 Hz
VAC
VAC
VAC
Ohm
VA
506
R06
6
4.8 / 5.4
1.8
11+10%
1.0 / 0.85
512
R12
12
9.6 /10.8
3.6
48+10%
1.0 / 0.85
524
R24
24
19.2 / 21.6
7.2
192+10%
1.0 / 0.79
548
R48
48
38.4 / 43.2 14.4
777+10%
1.0 / 0.87
560
R60
60
48.0 / 54.0 18.0
1306+10%
1.0 / 0.87
615
S15
115
92.0 /103.5 34.5
4845+12%
1.0 / 0.86
730
T30
230 184.0 / 207.0 69.0 19465+15%
1.0 / 0.90
All figures are given for coil without preenergization, at ambient temperature +23°C
Insulation
Dielectric strength coil-contact circuit
open contact circuit
adjacent contact circuits
Clearance / creepage coil-contact circuit
adjacent contact circuits
Material group of insulation parts
Insulation to IEC 61810-1
Type of insulation coil-contact circuit
open contact circuit
adjacent contact circuits
Rated insulation voltage
Pollution degree
Rated voltage system
Overvoltage category
2500 Vrms
1200 Vrms
2500 Vrms
W 3.1 / 3.1 mm
W 4.4 / 8.8 mm
IIIa
basic
micro disconnection
basic
250 V
2
230 / 400 V
III
PCB layout / terminal assignment
Bottom view on pins
Other data
Mechanical endurance DC coil
AC coil
Material
RoHS - Directive 2002/95/EC
Environment
Ambient temperature range
Vibration resistance (function) NO / NC contact
Shock resistance (function) NO / NC contact
Category of protection
Processing
Resistance to soldering heat
Relay weight
Packaging unit
20x106 cycles
15x106 cycles
compliant
-40...+70°C
7/4g
20 / 5 g
RTII - flux proof
270°C / 10 s
30 g
20 pcs
S0507-AA
S0507-AB
Dimensions
Solder- and plug-in terminals (standard version)
PCB version
Datasheet Rev. IJ1
Issued 2009/10
www.tycoelectronics.com
www.schrackrelays.com
S0505-BB
S0505-BA
2
Dimensions are in mm unless Product specification
processing information only in the ‘Schrack’ section.
otherwise specified and are
according to IEC 61810-1.
to be used together with the
shown for reference purposes Product data, technical para- 'Definitions' section in the cat- Specifications subject to
only.
meters, test conditions and