HARTMAN Aerospace Power Products
GeneralOperatingSpecifications
Physical Data
Main contact arrangement
Form
Auxiliary contact arrangement
Weight
SPST-NO
X
Up to 2 Form Z or C
0.50 lbs - 0.75 lbs
Environmental Data
Shock, 11ms 1/2 sine (operating)
Vibration, sine 10-2000 Hz
Vibration, random 10-2000 Hz
Operating temperature range
Storage temperature range
25 Gpeak
10 Grms
5 Grms
-55 to +85°C
-55 to +125°C
Typical Schematic Diagram
Main Contacts Electrical Data
Rated operating voltage
32 Vdc maximum
Load polarity (make, carry, break)
Bi-directional
Continuous current carry
200 Amps/300 Amps/400 Amps
In-rush current
1000 Amps/1500 Amps/2000 Amps
Maximum interrupt (50 times)
2000 Amps/3000 Amps/4000 Amps
Electrical current switching life @ 28Vdc
Resistive load (make, carry, break)
Motor load (make, carry, break)
50K cycles minimum
50K cycles minimum
Notes
Inductive load (make, carry, break)
Maximum contact voltage drop @ rated amps (see note 2)
Insulation resistance @ 500 Vdc
Dielectric withstanding voltage @ sea level
50K cycles minimum
0.125 Vdc
100 Milliohms
1800 Vrms
1. Auxiliary contacts are gold plated. 1 mA
rating does not apply if contacts have
switched loads above 1 mA.
(leakage less than 1.0 mA, 1 minute continuous)
2. 150 mV After Life test.
Auxiliary Contacts Electrical Data
Rated operating voltage
Load polarity (make, carry, break)
Continuous current carry
28 Vdc/115 Vac 3. Dropout is 3.5 Vdc max when used as a
Bi-directional
start contactor with the coil center tap
5 Amps
utilized.
Low level (see note 1)
1 mA
Mechanical Data
Operate time @ 18-32 Vdc
Dropout time @ 18-32 Vdc
Bounce @ 18-32 Vdc
Mechanical life @ 25% rated resistive load
35 Ms maximum
20 Ms maximum
4 Ms maximum
100K cycles
Coil Data
Duty cycle
Maximum operate voltage
Nominal operate voltage
Maximum pickup voltage
Maximum dropout voltage (see note 3)
Coil current @ 32 Vdc and -55°C
Inrush (12 mS max)
Holding
Nominal coil resistance @ 22°C
Pickup
Holding
Nominal coil power
Coil transient suppression
Continuous
32 Vdc
28 Vdc
16 Vdc
9 Vdc
5.5 Amps maximum
0.400 Amps maximum
5.5 ohms
86.5 ohms
9.1 watts
42 Vdc maximum
For factory-direct application assistance, contact the HARTMAN
product team at (419) 521-9500, Fax (419) 526-2749.
© 2004 by Tyco Electronics Corporation. All Rights Reserved.
HARTMAN and TYCO are trademarks.
Catalog (web doc only)
Revised 5-04
www.tycoelectronics.com
Dimensions are in inches and
millimeters unless otherwise
specified. Values in brackets
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA: 1-800-522-6752
Canada: 1-905-470-4425
Mexico: 01-800-733-8926
C. America: 52-55-5-729-0425
South America: 55-11-3611-1514
Hong Kong: 852-2735-1628
Japan: 81-44-844-8013
UK: 44-141-810-8967