TABLE III. AUTOMOTIVE SPECIFIC STRESS TESTS AND TEST CONDITIONS:
ELECTRICAL STRESS TESTS
ESD Voltage Withstand
(See note 1)
Short Circuit Fault Current Durability
TEST CONDITIONS (see note 2)
25kV
25 cycles, 16V, 200A
Fault Current Durability
End-of-life Mode Verification
Jump Start Endurance
(See note 1)
Load Dump Endurance
(See note 1)
350 cycles, 16V/100A
1750 cycles, 16V/100A
3 cycles, 26V, 1 minute duration
10 cycles, 86.5V
Note 1: The PolySwitch devices are tested in series with a load resistance and the voltages specified in the test conditions are
shared between the PolySwitch device and the load resistance as specified in PS400.