English
Language : 

2-1393147-8 Datasheet, PDF (2/3 Pages) Tyco Electronics – Power Relay RM 8
General Purpose Relays
Industrial Relays
Power Relay RM 8 (Continued)
SCHRACK
Coil Data (continued)
Coil versions, AC coil
Coil code
Rated Operate Release
Coil Rated coil
STD LED voltage voltage voltage resistance power
50/60Hz 50/60Hz
50/60Hz
VAC
VAC
VAC Ω±10%1)2)
VA
506 R06
6
4.8/5.1
1.8
4.7
2.86/2.36
512 R12
12
9.6/10.2 3.6
19.5 2.71/2.27
524 R24
24
19.2/20.4 7.2
80
2.62/2.00
548 R48
48
38.4/40.8 14.4
320 2.60/2.17
560 R60
60
48.0/51.0 18.0
500 2.62/2.20
615 S15
115
92.0/97.8 34.5
1850 2.65/2.22
730 T30
230 184.0/195.5 69.0
7500 2.69/ 2.26
900 V00
400 320.0/340.0 120.0 235002) 2.61/2.20
2) Coil resistance ±15%
All figures are given for coil without pre-energization, at ambient temperature +23°C
Terminal assignment
Bottom view on pins
Insulation Data
Initial dielectric strength
between open contacts
between contact and coil
between adjacent contacts
Initial surge withstand voltage
between contact and coil
between adjacent contacts
Clearance/creepage
between contact and coil
between adjacent contacts
Material group of insulation parts
1500Vrms
2500Vrms
4000Vrms
5000V(1.2/50µs)
6000V(1.2/50µs)
≥4.0/14.9mm
≥15.3/15.3mm
IIIa
Other Data
Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content
refer to the Product Compliance Support Center at
www.te.com/customersupport/rohssupportcenter
Ambient temperature
DC coil
-45 to +65°C
AC coil
-45 to +40°C
16 A contact load
-45 to +70°C
Category of environmental protection
IEC 61810
RTI - dust protected
Vibration resistance (functional)
form A (NO)/form B (NC)
10/5g, 30 to 150Hz
Terminal type
quick-connect
Cover retention, pull/push force
100/100N
Weight
81g
Packaging unit
10/25 pcs.
S0269-AG
Dimensions
Cover with mounting brackets, 6.3m​ m quick connect terminals
S0269-AD
Cover with DIN-snap-on attachement
horizontal
vertical
2
04-2011, Rev. 0411
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
S0298-BC
S0298-BD
S0298-BE
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.