English
Language : 

2-1393136-3 Datasheet, PDF (2/2 Pages) Tyco Electronics – CMOS IC Time Delay Relay
Catalog 1308242
Issued 3-03
Ordering Information – Authorized distributors are more likely to stock boldface items listed below.
P&B
Delay on Operate Models
Voltage Time
24VAC
0.1 to 10 Sec.
1.8 to 180 Sec
120VAC
0.1 to 1 Sec.
0.1 to 5 Sec.
0.1 to 10 Sec.
0.6 to 60 Sec.
1.8 to 180 Sec.
1 to 10 Min.
10 to 100 Min.
12VDC 0.1 to 10 Sec.
24VDC
0.1 to 1 Sec.
0.1 to 10 Sec.
0.6 to 60 Sec.
1.8 to 180 Sec.
Adjustment
Knob
Knob
Knob
Knob
Wiring Dia.
1
1
1
1
Part Number
CB-1041B-30
CB-1042B-30
CB-1001B-70
CB-1002B-70
CB-1003B-70
CB-1004B-70
CB-1005B-70
CB-1006B-70
CB-1007B-70
CB-1047D-20
CB-1026D-30
CB-1028D-30
CB-1029D-30
CB-1030D-30
Delay on Release Models
Voltage Time
24VAC
0.1 to 10 Sec.
1.8 to 180 Sec
120VAC
0.1 to 10 Sec.
0.1 to 10 Sec.
0.6 to 60 Sec.
1.8 to 180 Sec.
24VDC 0.1 to 10 Sec.
1.8 to 180 Sec.
Interval on Models
Voltage Time
24VAC 0.1 to 10 Sec.
120VAC
0.1 to 5 Sec.
0.1 to 10 Sec.
1 to 10 Min.
24VDC 0.1 to 5 Sec.
1.8 to 180 Sec.
Adjustment
Knob
Knob
Knob
Adjustment
Knob
Knob
Knob
Wiring Dia.
3
3
5
3
3
3
Part Number
CB-1045B-38
CB-1046B-38
CB-1021B-78
CB-1022B-78
CB-1023B-78
CB-1024B-78
CB-1038D-38
CB-1039D-38
Wiring Dia.
1
1
1
1
1
Part Number
CB-1043B-39
CB-1011B-79
CB-1014B-79
CB-1018B-79
CB-1034D-39
CB-1036D-39
Outline Dimensions
2.406 MAX.
(61.1)
.60
(15.2)
➛
2.937 MAX.
(74.6)
➛
.56
(14.2)
1.781 MAX.
(45.2)
➛
Wiring Diagrams - Bottom Views (pins numbered clockwise from keyway)
EXTERNAL
CONTROL
SWITCH*
EXTERNAL
CONTROL
SWITCH*
+
_
INPUT (DC POLARITY
INDICATED)**
Fig. 1
8 Pin
+
_
CONTINUOUS
SUPPLY
INPUT
(DC POLARITY INDICATED)**
Fig. 3
11 Pin
+
_
CONTINUOUS
SUPPLY
INPUT
(DC POLARITY INDICATED)**
Fig. 5
8 Pin
* If control switch is closed when power is applied, relay will immediately energize. A 50 millisecond minimum switch closure is required. IMPORTANT: A dry circuit switch is recommended. A
“dry circuit” switch is one rated to reliably switch currents of less than 50mA. Use of a switch rated for other than dry circuit may result in failure of the time delay relay to function properly.
** Note: Input polarity for DC operation. For most reliable operation on AC, connect high side to “+” and low side to “–”.
Dimensions are shown for
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
1229
Refer to inside back cover.