1108846-1 Datasheet, PDF (2/4 Pages) Tyco Electronics – Power4Net Hybrid Connector for Industrial Automation | |||
|
◁ |
TE Connectivity
Power4Net hybrid connector
KEY FEATURES
⢠Hybrid design, combining
power and data communication
⢠Housing with 8 power contacts
and fast Ethernet interface
⢠Optional housing with 11 + PE
(Protection Earth) contacts
⢠Wire-to-board, wire-to-panel
and wire-to-wire designs
⢠Extremely robust contact
design for longer durability with
stainless steel locking lance and
multiple contact points
⢠Gold, silver and tin plated
contacts for industrial
automation requirements
⢠Radial sealing elements provide
IP67 sealing performance
⢠Hydraulic oil-resistant plastic
enclosures or EMC protected
metal enclosures
⢠Bulkhead, connector and wire-
to-wire connectors in 90° and
180° designs
⢠Turning catch-lock ensures safe
locking even in high shock and
vibration applications
APPLICATIONS
⢠High-performance process control systems applications
⢠Machine automation applications
⢠Factory automation systems
⢠Control valves and control units
⢠Stand-alone or remote power units
⢠Railway systems and outdoor transportation control systems
MECHANICAL
⢠Shock: 25 g (DIN EN 50155)
⢠EMC: min -60dB to 1 GHz
⢠Isolation level: 1.5 kV AC
⢠Durability: 50 mating/un-mating cycles
Electrical
⢠Voltage: 60 V (pollution degree 3, according EN 61984)
⢠Ampacity: 10 A @ 40°C
⢠Operating temperature: -20°C up to +80°C
⢠Protection: IP67 (according to IEC 60529)
⢠Communication: Cat5e (ISO/IEC 11801 Edition 2.0 Connector Category 5)
MATERIALS
⢠Housings: Hydraulic oil-resistant plastic or EMC protected metal
⢠Contacts: Copper alloy with gold, silver and tin plated versions
⢠Interfacial and wire entry seals: UV protected silicone
STANDARDS
⢠Meets VARAN standard (Versatile Automation Random Access Network),
an Industrial Ethernet based protocol used in factory automation
⢠Cat5e fast Ethernet (ISO/IEC11801)
⢠DIN EN 61984
⢠SIL-3, IEEE61508, PL e
te.com/products/Power4Net
|
▷ |