English
Language : 

VTM3 Datasheet, PDF (1/1 Pages) Tyco Electronics – Interval Timing Module
Catalog 1308242
Issued 3-03
VTM3 series
Interval
Timing Module
• Interval timing mode
• Reliable solid state timing circuitry.
• Excellent transient protection.
• Compact design.
• Flame retardant, solvent resistant housing.
AGASTAT
Timing Mode
Interval.
Timing Specifications
Timing Ranges: 0.5 to 10 / 3 to 60 sec.; 3 to 60 min.
Timing Adjustment: External resistor or potentiometer. An external
resistance of 1 megohm is required to obtain the
maximum time for all ranges. To determine the actual
resistance needed to obtain the required time delay,
use the following formula:
( ) Rt =
Treq - Tmin
Tmax - Tmin
x 1,000,000 ohms
Accuracy: Repeat Accuracy: ± 1%
Overall Accuracy: ± 2% at R = 1 megohm.
Reset Time: 50 ms, max.
Output Switch Data
Arrangement: Solid state 1 Form A (SPST-NO).
Rating: 1A, inductive, at nominal operating voltage.
Expected Electrical Life: 100,000,000 operations at rated load.
Initial Dielectric Strength
Between Terminals and Mounting: 3,000VAC rms.
Between Input and Output: 1,500VAC rms.
Outline Dimensions
2.00
(50.8)
1.25
(31.8)
.885
(22.5)
2.00
(50.8)
File E60363
File LR33434
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that user also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Input Data @ 25°C
Voltage:(±10%): 12 VAC/VDC, 24VAC/VDC, 120 VAC/VDC.
Power Requirement: 4W, with rated load.
Transient Protection: Non-repetitive transients of the following magni-
tudes will not cause spurious operation of affect function and accuracy.
Operating Voltage <0.1 ms
<1 ms
12, 24 VAC/VDC
860V*
208V*
120 VAC/VDC
2,580V
2,150V*
* Min. source impedance of 100 ohms.
Current Drain: Less than 5mA.
Environmental Data
Temperature Range: Storage: -40°C to +85°C.
Operating: -40°C to +65°C.
Mechanical Data
Mounting: Panel mount with one #8 screw.
Termination: 0.250 in (6.35) quick connect terminals.
Weight: 4 oz. (112g) approximately.
Ordering Information
VTM3
|
Series VTM3
Interval
Timing Module
A
|
Input Voltage
A = 120VAC/VDC
E = 24VAC/VDC
Q = 12VAC/VDC
CD
|
Time Range
CD = 0.5 - 10 sec.
DD = 3 - 60 sec.
GD = 3 - 60 min.
.170 DIA (4.32)
.250 (6.35) X .032 (.813)
ACCEPTS #8 SCREW QUICK CONNECTS
Wiring Diagram
POLARITY SHOWN
FOR DC
MODELS
LOAD 1
2
INPUT
VOLTAGE
3
An external resistance of 1 megohm is
required to obtain the maximum time
for all ranges. To determine the actual
5
resistance needed to obtain the
Rt required time delay, use the following
4
formula:
( ) Rt =
Treq - Tmin
Tmax - Tmin
x 1,000,000 ohms
Authorized distributors are likely to stock the following:
None at present.
Dimensions are shown for
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
1245
Refer to inside back cover.