AGASTAT
STA series
Timing Modes
On-Delay, Off-Delay, Interval and Accumulating On-Delay.
Timing Specifications
Timing Ranges: 6 to 180 cycles; 0.1 to 3 / 0.5 to 15 / 1 to 30 / 2 to 60 /
4 to 120 / 6 to 180 / 10 to 300 sec.; 0.33 to 10 / 0.5 to 15 /
1 to 30 min.; 1 to 6 / 2 to 48 hr. (All are +5%, –0% of
maximum values).
Timing Adjustment: Knob or fixed time (internal fixed resistor) – all models;
customer supplied external potentiometer or resistor
– On-Delay and Interval models only.
Accuracy: Repeat Accuracy: ± .5% ± 0.004 sec..
Overall Accuracy: ± 2% throughout operating temperature
and voltage ranges.
Reset Time: 30 ms. min. (between deenergization and reenergization
without affecting accuracy.)
Relay Operate Time: Off-Delay mode: 35 ms.; Interval mode: 20 ms.
Relay Release Time: On-Delay and Accumulating On-Delay modes: 20 ms.
Contact Data @ 25°C
Arrangements: 2 Form C (DPDT).
Rating: 10A @ 28VDC or 120VAC, resistive; 1/3 HP @ 120/240VAC; 345VA.
Same polarity.
Expected Mechanical Life: 10 million operations.
Expected Electrical Life: 500,000 operations, min., at rated resistive load.
Initial Dielectric Strength
Between Terminals and Case: 1,000VAC plus twice the nominal voltage
for one minute.
Outline Dimensions
1.500 MAX.
(38)
1.390 MAX.
(35)
.660 MAX.
(17)
3.045
(77)
.281 REF.
(7)
Wiring Diagrams (Bottom Views)
Insulated, shielded two-conductor
cable similar to Belden 8719, 8720
or 8769 required for leads longer
than 6 inches. Maximum
permissble length is 50 feet.
Off-Delay &
Accumulating
On-Delay
Fixed or Knob
Adjust
Dimensions are shown for
1236 reference purposes only.
On-Delay
&
Interval
Fixed or Knob
Adjust
On-Delay
&
Interval
External Potentiomer
or Resistor Adjust
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specification Grade Discrete Plug-in
Time Delay Relay With QC Terminals
• On-Delay, Off-Delay, Interval and Accumulating On-Delay
timing modes
• 13 timing ranges from 0.1 sec. to 48 hr.
• 10A DPDT output contacts
• Knob, fixed or external timing adjustment.
• QC plug-in terminals save space, two LEDs show status
File E60363
®
File LR51332
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that user also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Input Data @ 25°C
Voltage: See Ordering Information section for details.
Power Requirement: 3W, max.
Transient Protection: Non-repetitive transients of the following magni-
tudes will not cause spurious operation of affect function and accuracy.
Operating Voltage
All except 12 & 24
<0.1 ms
3,000V
<1 ms
2,500
12 & 24
Consult Factory
Environmental Data
Temperature Range: Storage: -40°C to +85°C.
Operating: -30°C to +65°C.
Mechanical Data
Mounting/Termination: Quick connect terminals fit either 27E121 or
27E893 (snap-on) socket (order separately).
Status Indication: Power On LED and Output Contacts LED (optional).
Weight: 4.2 oz. (119g) approximately.
Ordering Information (All "X's" must be included to complete part number)
STA RX 01 2X S A
A XA
||
|
| ||
Series STA | Operating Mode | Status |
Discrete
Industrial
Timer
With
Tab-type
| 01 = On-Delay | Indication |
|
|
02
03
09
=
=
=
Off-Delay
Interval
Accumulating
|
|
S = LEDs
X = No LEDs
|
|
| On-Delay |
|
Terms. |
Output
|
|
2X = DPDT
|
Mounting Series
Relay
|
RX = 11-pin tab-type
|
header (order
socket
separately)
|
|
|
|
|
Timing Range |
A =0 .1 to 3 sec. |
B = 0.5 to 15 sec.
C = 1 to 30 sec.
D = 2 to 60 sec.
|
|
E = 4 to 120 sec. |
F = 6 to 180 sec. |
G = 10 to 300 sec.
I = 2 to 60 min.
|
J = 1 to 6 hr.
|
K = 3 to 180 cycles |
L = 0.33 to 10 min.
M = 0.5 to 15 min.
N = 1 to 30 min.
|
|
R = 2 to 48 hr. |
Operating Voltage
(+10%, –15%)
A = 120VAC, 50/60
Hz. / 120VDC
E = 24VAC, 50/60
Hz. / 24VDC
F = 48VAC, 50/60
Hz. / 48VDC
Q = 12VDC
Timing Adjustment
XA = Knob Adjust
XB = External
Potentiometer or
resistor (Operating
modes 1 and 3
only).
XF =Fixed Times –
Specify time delay
in seconds per the
following examples:
XF9.000 = 9 sec.
XF99.00 = 99 sec.
XF999.0 = 9999 sec.
XF1000 = 1000 sec.
Authorized distributors are likely to stock the following:
None at present.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.