English
Language : 

SRC Datasheet, PDF (1/1 Pages) Tyco Electronics – Specification Grade Repeat Cycle
Catalog 1308242
Issued 3-03
AGASTAT
SRC series
Specification Grade Repeat Cycle
Plug-in Time Delay Relay
• Repeat Cycle timing mode
• Dual knobs for user adjustment of on and off times.
• 13 timing ranges from 0.1 sec. to 60 min.
• 10A DPDT output contacts
• Exceptional immunity to line transients and noise
• Premium components enhance reliability
• Superior reset time of 24 msec.
Timing Modes
Repeat Cycle: Application of line voltage starts the pre-set OFF-time period
Upon expiration of the period, the output relay is energized, its contacts
transfer, and the pre-set ON-time period begins. At the end of this period
the output relay is deenergized, and a new cycle begins. The OFF and ON
cycles continue until power is removed. To reset the timer, input voltage
must be removed for at least 25 ms.
Timing Specifications
Timing Ranges: OFF time and ON time ranges need not be the same.
6 to 180 cycles; 0.1 to 3 / 1 to 10 / 0.5 to 15 / 1 to 30 / 2 to
60 / 4 to 120 / 6 to 180 / 10 to 300 sec.; 0.33 to 10 / 0.5 to
15 / 1 to 30 / 2 to 60 min. (All are +10%, –1% of maximum
values).
Timing Adjustment: Two internal potentiometers with external knobs.
Accuracy: Repeat Accuracy: ± 1% ± 0.004 sec..
Overall Accuracy: ± 2.25% max.
Reset Time: 25 ms. max. (between deenergization and reenergization
without affecting accuracy.)
Relay Operate Time: 20 ms.
Relay Release Time: 15 ms.
Contact Data @ 25°C
Arrangements: 2 Form C (DPDT).
Rating: 10A @ 28VDC or 120VAC, resistive; 1/3 HP @ 120/240VAC.
Expected Mechanical Life: 10 million operations.
Expected Electrical Life: 500,000 operations, min., at rated resistive load.
Initial Dielectric Strength
Between Terminals & Case and Mutually Isolated Contacts: 1,480VAC.
Outline Dimensions
1.97
(50)
.40
(10)
1.97
(50)
3.7 MAX.
(94)
Wiring Diagram (Bottom View)
Dimensions are shown for
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that user also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Input Data @ 25°C
Voltage: See Ordering Information section for details.
Power Requirement: 3W, max.
Transient Protection: Non-repetitive transients of the following magni-
tudes will not cause spurious operation of affect function and accuracy.
Operating Voltage
12VDC
<0.1 ms
1,000V
<1 ms
240V*
24VAC/VDC
48 VAC/VDC
120 VAC/VDC
1,000V
1,000V
3,000V
240V*
480V*
2,500V*
240VAC
3,000V
2,500V*
* Minimum source impedance of 100 ohm.
Environmental Data
Temperature Range: Storage: -40°C to +85°C.
Operating: -30°C to +65°C.
Mechanical Data
Mounting/Termination: Quick connect terminals fit either 27E121 or
27E893 (snap-on) socket (order separately).
Weight: 5.3 oz. (149g) approximately.
Ordering Information
SRC 7 2 A
C
C
A
| |||
|
|
|
Series SRC | Output |
Timing Range
|
Timing
Repeat
Cycle
Timer.
| 2 = DPDT |
| Relay |
|
|
Operating Mode
|
7= Repeat Cycle
|
|
|
Off-Time
A =0 .1 to 3 sec.
B = 0.5 to 15 sec.
C = 1 to 30 sec.
D = 2 to 60 sec.
E = 4 to 120 sec.
F = 6 to 180 sec.
G = 10 to 300 sec.
I = 2 to 60 min.
|
Adjustment
|
|
A = Dual Knob
Adjust
|
|
|
|
| K = 3 to 180 cycles
|
|
|
L = 0.33 to 10 min.
M = 0.5 to 15 min.
N = 1 to 30 min.
Timing Range
On-Time
|
P = 0.1 to 10 sec. A =0 .1 to 3 sec.
B = 0.5 to 15 sec.
Operating Voltage
C = 1 to 30 sec.
(+10%, –15%)
A = 120VAC, 50/60
Hz. / 120VDC
B = 240VAC, 50/60
Hz.
E = 24VAC, 50/60
D = 2 to 60 sec.
E = 4 to 120 sec.
F = 6 to 180 sec.
G = 10 to 300 sec.
I = 2 to 60 min.
K = 3 to 180 cycles
Hz. / 24VDC
F = 48VAC, 50/60
Hz. / 48VDC
Q = 12VDC
L = 0.33 to 10 min.
M = 0.5 to 15 min.
N = 1 to 30 min.
P = 0.1 to 10 sec.
Authorized distributors are likely to stock the following:
None at present.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
1237
Refer to inside back cover.