English
Language : 

RT424A12 Datasheet, PDF (1/3 Pages) Tyco Electronics – Power PCB Relay RT2 bistable
General Purpose Relays
Power PCB Relay RT2 bistable
I 2 pole 8 A, 2 CO contacts
I Polarized bistable version with 1 or 2 coils
I 5 kV / 10 mm coil-contact
I Reinforced insulation
I RoHS compliant (Directive 2002/95/EC)
as per product date code 0413
Applications
Battery powered equipment or applications with "memory
function" (e.g. mains failure)
F0219-B
Approvals
V Z REG.-Nr. 6106,
E214025
Technical data of approved types on request
Contact data
Contact configuration
Contact set
Type of interruption
Rated current
Rated voltage / max.switching voltage AC
Limiting continuous current
Maximum breaking capacity AC
Limiting making capacity, max 4 s, duty factor 10%
Contact material
Mechanical endurance
Rated frequency of operation with / without load
2 CO
single contact
micro disconnection
8 A, UL: 10 A
240/400 VAC
UL: 10 A
2000 VA
15 A
AgNi 90/10
> 2 x 106 cycles
15 / 1200 min-1
Coil data
Rated coil voltage range
Coil power
Operative range
Limiting voltage, % of rated coil voltage
Minimum energization duration
Maximum energization duration
Coil insulation system according UL1446
1 coil
2 coils
5...24 VDC
typ 400 mW
typ 600 mW
2
120%
150%
30 ms
1 min at < 10% DF
class F
Coil versions, bistable DC-coil
Coil
Rated
Operate
Reset
Coil
Rated coil
code
voltage
voltage
voltage
resistance
power
VDC
VDC
VDC
c
mW
bistable, 1 coil
A05
5
3.5
3.5
62+10%
403
A06
6
4.2
4.2
90+10%
400
A12
12
8.4
8.4
360+10%
400
A24
24
16.8
16.8
1440+10%
400
bistable, 2 coils
F05
5
3.5
3.5
42+10%
595
F06
6
4.2
4.2
55+10%
655
F12
12
8.4
8.4
240+10%
600
F24
24
16.8
16.8
886+10%
650
All figures are given for coil without preenergization, at ambient temperature +23°C
Other coil voltages on request
Datasheet
Rev. EK1
Issued 2005/11
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
processing information
only to be used together
with the 'Definitions' at
schrackrelays.com in the
1
‘Schrack’ section.
Specifications subject to
change.