General Purpose Relays
Interface Power Relay RT
I 1 pole 12 / 16 A, 2 pole 8 A, 1 CO contact or 2 CO contacts
I DC- or AC coil
I Sensitive coil 400 mW
I Reinforced insulation, protection class II (VDE 0700)
I 5 kV / 10 mm coil-contact
I 1 pole 12 A with 3.5 or 5 mm pinning
I Recycleable packaging
Applications
Panel boards, mechanical engineering
Approvals
V Z REG.-Nr. 6106,
E214025
Technical data of approved types on request
Contact data
1-pole
2-pole
Contact configuration
1 CO
2 CO
Contact set
single contact
Type of interruption
micro disconnection
Rated voltage / max. switching voltage AC
240 / 400 VAC
Rated current
12 / 16 A
8A
Maximum breaking capacity AC
3000 / 4000 VA
2000 VA
Limiting making capacity,max 4 s, df 10%
25 / 30 A
15 A
Contact material
AgNi 90/10
Rated frequency of operation DC coil with / without load 6 / 1200 min-1
AC coil with / without load
6 / 600 min-1
Operate- / release time DC coil
max 8 / 6 ms
max 10 / 5 ms
Bounce time DC coil, NO / NC contact
max 4 / 6 ms
max 4 / 9 ms
Contact ratings
Type
Contact Load
Ambient
temp. [°C]
IEC 61810
RT314 DC-coil NO
10 A, 400 VAC, cosϕ=1
85°C
RT314 AC-coil NO
16 A, 250 VAC, cosϕ=1
70°C
RT314 AC-coil CO
16 A, 250 VAC, cosϕ=1
70°C
RT424 AC coil CO
8 A, 250 VAC, cosϕ=1
70°C
UL 508
RT314
NO
16 A, 250 VAC, general purpose, DF: 10% 85°C
RT314
NO
A300
40°C
RT314
NC
B300
40°C
RT314
NO
240 VAC, 1 hp
40°C
RT424 DC coil NO / NC 8 A, 30 VDC, general purpose
85°C
RT424 DC coil NO
10 A, 250 VAC, general purpose
85°C
RT424 DC coil NO / NC motor, 1/2 hp, 240 VAC
85°C
RT424 DC coil NO / NC pilot duty, B300, R300
85°C
EN60730-1
RT314 DC-coil NO
12(2) A, 250 VAC
85°C
RT424 DC coil NO / NC 6(2) A, 250 VAC
85°C
Cycles
150x103
50x103
10x103
30x103
50x103
6x103
6x103
1x103
6x103
30x103
1x103
6x103
100x103
100x103
Coil data
Rated coil voltage range DC coil
AC coil
Operative range to IEC 61810
Coil insulation system according UL1446
5...110 VDC
24...230 VAC
2
class F
SCHRACK
F0269-C
Datasheet Rev. HK1
Issued 2008/11
www.tycoelectronics.com
www.schrackrelays.com
1
Dimensions are in mm unless Product specification
processing information only in the ‘Schrack’ section.
otherwise specified and are
according to IEC 61810-1.
to be used together with the
shown for reference purposes Product data, technical para- 'Definitions' section in the cat- Specifications subject to
only.
meters, test conditions and
alogue or at schrackrelays.com change.