English
Language : 

RP827012 Datasheet, PDF (1/2 Pages) Tyco Electronics – Power PCB Relay RPII/2
General Purpose Relays
PCB Relays
Power PCB Relay RPII/2
n 2 pole 8A, 2 form C (CO) or 2 form A (NO) contacts
n 4kV/8mm coil-contact
n Twin contacts available
n RoHS compliant (Directive 2002/95/EC)
SCHRACK
Typical applications
Domestic appliances, UPS
VZ
F0150-B
Approvals
VDE REG.-Nr. C894, UL E214024
Technical data of approved types on request
Contact Data
Contact arrangement 2 form C (CO) or 2 form A (NO)
Rated voltage
250VAC
Max. switching voltage
400VAC
Rated current
8A (UL: 10A)
Limiting making current, max 4s, duty factor 10% 14A
Breaking capacity max.
2000VA
Contact material
AgCdO, AgNi0.15
Frequency of operation, with/without load
600/72000h-1
Operate/release time typ.
9/3ms
Bounce time typ., form A/form B
2/3ms
Contact ratings
Type
Contact
IEC61810
RP420/421 A (NO)
RP420
A (NO)
Load
8A, 250VAC, resistive, 35°C
5A, 250VAC, resistive, 70°C
Cycles
100x103
30x103
Mechanical endurance
>20x106 operations
Coil Data
Coil voltage range
Operative range, IEC 61810
5 to 110VDC
2
Coil versions, DC coil
Coil
Rated
Operate Release
Coil
Rated coil
code
voltage
voltage
voltage resistance power
VDC
VDC
VDC
Ω±10%1)
mW
005
5
3.5
0.5
54
500
006
6
4.2
0.6
68
500
012
12
8.4
1.2
270
500
024
24
16.8
2.4
11001)
500
048
48
33.6
4.8
44001)
500
060
60
42.0
6.0
65401)
500
110
110
77.0
11.0
231001)
500
1) Coil resistance ±15%.
All figures are given for coil without pre-energization, at ambient temperature +20°C.
Other coil voltages on request.
Insulation Data
Initial dielectric strength
between open contacts
between contact and coil
between adjacent contacts
Clearance/creepage
between contact and coil
Material group of insulation parts
1000Vrms
4000Vrms
2500Vrms
≥8/8mm
IIIa
04-2011, Rev. 0411
www.te.com
© 2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
1
Datasheets and product data is subject to the Datasheets, product data, ‘Definitions’ sec-
terms of the disclaimer and all chapters of
tion, application notes and all specifications
the ‘Definitions’ section, available at
are subject to change.
http://relays.te.com/definitions