English
Language : 

PTF Datasheet, PDF (1/3 Pages) Tyco Electronics – Miniature Power Relay
General Purpose Relays
Miniature Power Relay PTF
I 2 pole 15 A, 2 CO contacts
I DC or AC coil
I Plug-in version, PCB or chassis mount version
I RoHS compliant (Directive 2002/95/EC)
Applications
Panel boards, domestic appliances
F0281-A
Approvals
V Z REG.-Nr. A379,
E58304
Technical data of approved types on request
Contact data
Contact configuration
Contact set
Type of interruption
Rated current
Rated voltage / max.switching voltage AC
Maximum breaking capacity AC
Limiting making capacity, max 20 ms
Contact material
Minimum contact load
Mechanical endurance DC coil
AC coil
Rated frequency of operation with / without load
Contact ratings
Type Load
PTF2 15 A, 120 VAC, NO, DC coil / AC coil
PTF2 10 A, 250 VAC, NO, DC coil / AC coil
PTF2 10 A, 24 VDC, NO, DC coil / AC coil
2 CO contacts
single contact
micro disconnection
10 A / 250 VAC
15 A / 120 VAC
240/400 VAC
2500 VA / 250 VAC
1800 VA / 120 VAC
20 A / 250 VAC
30 A / 120 VAC
AgNi90/10
5V/100mA
20x106 cycles
15x106 cycles
6/600 min-1
Cycles
100x103 / 50x103
200x103 / 100x103
100x103 / 50x103
Coil data
Rated coil voltage range DC coil
AC coil
Coil power DC coil
AC coil
Operative range DC coil, AC-coil 50Hz
AC coil 60 Hz at 70°C, % of Urtd
6...220 VDC
6...230 VAC
0.75 W
1.0 VA
2
90..110%
Coil versions, DC-coil
Coil code
Rated
Operate Release
Coil
Rated coil
STD
LED
voltage
voltage
voltage resistance
power
bipolar
VDC
VDC
VDC
Ohm
mW
006
L06
6
4.5
0.6
48+10%
750
012
L12
12
9.0
1.2
192+10%
750
024
L24
24
18.0
2.4
777+10%
741
048
L48
48
36.0
4.8
3072+10%
750
060
L60
60
45.0
6.0
4845+12%
743
110
M10
110
82.5
11.0 16133+15%
750
220
N20
220
165.0
22.0 64533+15%
750
All figures are given for coil without preenergization, at ambient temperature +23°C
Datasheet
Rev. EK1
Issued 2005/11
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical para-
meters, test conditions and
processing information
only to be used together
with the 'Definitions' at
schrackrelays.com in the
1
‘Schrack’ section.
Specifications subject to
change.