English
Language : 

MASWSS0093 Datasheet, PDF (1/3 Pages) Tyco Electronics – GaAs Broadband SPDT Switch DC - 6.0 GHz
GaAs Broadband SPDT Switch
DC - 6.0 GHz
RoHS
Compliant
MASWSS0093
V2
Features
• UNII, Hiperlan, and 802.11a+b/g Applications
• Broadband Performance: DC-6 GHz
• Low Insertion Loss: 0.9 dB at 6 GHz
• High Isolation: 28 dB Typical
• Fast Switching Speed: 0.5 µm GaAs PHEMT
• High Power: 36 dBm P1dB
• Lead-Free 3 mm 12-lead PQFN Package
• 100% Matte Tin Plating over Copper
• Halogen-Free “Green” Mold Compound
• RoHS* Compliant and 260°C Reflow Compatible
Description
M/A-COM’s MASWSS0093 is a broadband GaAs
PHEMT MMIC SPDT switch in a low cost, lead-free
3 mm 12-lead PQFN package. The MASWSS0093
is ideally suited for applications where very small
size and low cost are required.
The MASWSS0093, with its small size and low
height, is ideal for 802.11a and 802.11b/g PC card
and access point applications.
The MASWSS0093 delivers high isolation, low
insertion loss and high linearity up to 6 GHz.
The MASWSS0093 is fabricated using a 0.5 micron
gate length GaAs PHEMT process. The process
features full passivation for performance and
reliability.
Ordering Information
Part Number
MASWSS0093
Package
Bulk Packaging
MASWSS0093TR
1000 piece reel
MASWSS0093SMB
Sample Test Board
(Includes 5 Samples)
Note: Reference Application Note M513 for reel size
information.
Functional Schematic
GND RFC GND
VC1
RF1
GND
VC2
RF2
GND
GND GND GND
Pin Configuration
PIN No.
PIN Name
Description
1
VC1
Control 1
2
RF1
RF Port 1
3
GND
Ground
4
GND
Ground
5
GND
Ground
6
GND
Ground
7
GND
Ground
8
RF2
RF Port 2
9
VC2
Control 2
10
GND
Ground
11
RFC
RF Input
12
GND
Ground
13
Paddle 1
RF and DC Ground
1. The exposed pad centered on the package bottom must be
connected to RF and DC ground.
Absolute Maximum Ratings 2,3
Parameter
Absolute Maximum
Input Power @ 3 V Control
+37 dBm
Input Power @ 5 V Control
+39 dBm
Operating Voltage
Operating Temperature
+8.5 volts
-40°C to +85°C
Storage Temperature
-65°C to +150°C
2. Exceeding any one or combination of these limits may cause
permanent damage to this device.
3. M/A-COM does not recommend sustained operation near
these survivability limits.
* Restrictions on Hazardous Substances, European Union Directive 2002/95/EC.
1
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.