MASW-007221 Datasheet, PDF (1/3 Pages) Tyco Electronics – GaAs SPDT Switch DC - 3.0 GHz
GaAs SPDT Switch
DC - 3.0 GHz
RoHS
Compliant
MASW-007221
V1
Features
• Low Insertion Loss: < 0.3 dB @ 900 MHz
• Low Power Consumption: < 15 µA @ -2.3 Volts
• Positive or Negative 2.3 to 8 Volt Control
• Lead-Free SC-70 (SOT-363) Package
• 100% Matte Tin Plating over Copper
• Halogen-Free “Green” Mold Compound
• 260°C Reflow Compatible
• RoHS* Compliant version of SW-456
Description
M/A-COM’s MASW-007221 is a GaAs monolithic
switch in a lead-free SC-70 (SOT-363) surface
mount plastic package. The MASW-007221 is
ideally suited for applications where very low power
consumption, low insertion loss, very small size, and
low cost are required. Typical applications are in
dual band systems where switching between small
signal components is required, i.e. filter banks,
single-band LNA’s, converters, etc.
Functional Schematic: Positive Control Voltage
PIN 1
RF1
1000 pF
GND
RF2
1000 pF
VCTL1
RFC
1000 pF
VCTL2
Functional Schematic: Negative Control Voltage
PIN 1
RF1
VCTL1
GND
RFC
The MASW-007221 can be used in applications up
to 0.25 watts in systems such as cellular, PCS,
RF2
VCTL2
DCS1800, GSM, CDMA, W-CDMA and other
analog / digital wireless communication systems.
The MASW-007221 is fabricated using a mature 0.5
micron PHEMT process. The process features full
passivation for performance and reliability.
Ordering Information 1
Part Number
MASW-007221-000000
Package
Bulk Packaging
MASW-007221-TR3000
3000 piece reel
1. Reference Application Note M513 for reel size information.
Pin Configuration
PIN
1
2
3
4
5
6
Function
RF1
GND
RF2
VCTL2
RFC
VCTL1
Description
RF In/Out
RF Ground
RF In/Out
Voltage Control 2
RF Common
Voltage Control 1
Absolute Maximum Ratings 2,3
Parameter
Absolute Maximum
Input Power (0.5 - 3.0 GHz)
3 V Control
5 V Control
+30 dBm
+33 dBm
Operating Voltage
+8.5 volts
Operating Temperature
-40°C to +85°C
Storage Temperature
-65°C to +150°C
2. Exceeding any one or combination of these limits may cause
permanent damage to this device.
3. M/A-COM does not recommend sustained operation near
these survivability limits.
* Restrictions on Hazardous Substances, European Union Directive 2002/95/EC.
1
M/A-COM Inc. and its affiliates reserve the right to make changes to the
• North America Tel: 800.366.2266 / Fax: 978.366.2266
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
whatsoever arising out of the use or application of any product(s) or
information.
Visit www.macom.com for additional data sheets and product information.