English
Language : 

LVR040S Datasheet, PDF (1/2 Pages) Tyco Electronics – PolySwitch PTC Devices Overcurrent Protection Device
Tyco/Electronics
Raychem Circuit Protection
308 Constitution Drive
Menlo Park, CA 94025-1164
800-227-4856
FAX 800-227-4866
PolySwitch®
PTC Devices
Overcurrent Protection Device
PRODUCT: LVR040S
DOCUMENT: SCD 24906
PCN: 336638
REV LETTER: E
REV DATE: MARCH 21, 2003
PAGE NO.: 1 OF 2
Specification Status: RELEASED
Electrical Rating at 20ºC
Rated Operating Voltage: 240 VAC
Rated Interrupt Current: 5.5 ARMS
Max Interrupt Voltage: 265 VAC
Insulating Material :
Cured, Flame Retardant Epoxy Polymer
Meets UL94 V-0 Requirements.
Lead Material: 22 AWG Sn Plated Copper
Marking:
240
L040
Raychem Logo
and Voltage
Part Identification
Lot Identification
(can be on back)
TABLE I. DIMENSIONS:
A
B
MIN MAX MIN MAX
mm:
-- 11.5
--
19.5
in*:
-- (0.46 -- (0.77)
*Rounded off approximation
C
MIN MAX
4.3
5.8
(0.17) (0.23)
D
MIN MAX
7.6
(0.30) --
E
MIN MAX
3.8
-- (0.15)
TABLE II. PERFORMANCE RATINGS:
IHOLD
RATED
CURRENT RATINGS
CURRENT
AMPS AT
20oC
HOLD
0.40
HOLD
0.40
AMPS
AT 20oC
TRIP
0.90
TIME TO TRIP
SECONDS AT
20oC, 2.0A
MAX
24.0
RESISTANCE
OHMS
AT 20oC
MIN MAX
0.6
0.97
POST-TRIP
RESISTANCE
STANDARD
TRIP
OHMS
AT 20oC
MAX
1.9
NOMINAL
TRIPPED
POWER
DISSIPATION
WATTS
AT 20oC
2.0
Recognitions:
Reference Documents:
Precedence:
Effectivity:
Warning:
UL, TUV recognized.
PS300
This specification takes precedence over documents referenced herein.
Reference documents shall be the issue in effect on the date of invitation for bid.
Refer to Page 2 of this document for application limitations.