English
Language : 

KUHP Datasheet, PDF (1/2 Pages) Tyco Electronics – 30 Amp Power Relays
Catalog 1308242
Issued 3-03
P&B
KUHP series
30 Amp Power Relays
File E22575
File LR15734-123
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that users also seek out the pertinent approvals files
of the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Features
• AC coils 6-277VAC 50/60 Hz., DC 6-110VDC.
• Contact arrangement up to DPDT.
• .250" combination push-on/solder terminals or PC terminals.
• Side flange and top flange mounting.
• Designed to meet VDE space requirements.
• Class B coil insulation.
Contact Data @ 25°C
Arrangements: 1 Form C (SPDT) and 2 Form C (DPDT).
Material: Silver or silver-cadmium oxide.
Expected Mechanical Life: 10 million operations.
Contact Ratings
Contact
Arrangement
1 Form C
Single Pole
Double Throw
2 Form C
Double Pole
Double Throw
*NO contacts only.
UL/CSA Ratings
30A 120/240VAC
1 HP @ 120VAC,
1 1/2 HP @ 240VAC
25A @ 28VDC
20A @ 120/240VAC
3/4 HP @ 120VAC
1 1/2 HP @ 240VAC
20A @ 28VDC
7A @ 120VAC (Tungsten)*
Initial Dielectric Strength
Between Open Contacts: 1,200V rms.
Between Adjacent Contacts: 3,750V rms.
Between Contacts and Coil: 3,750V rms.
Between Coil and Frame: 2,000V rms.
Expected
Life
100,000
ops.
100,000
ops.
Coil Data @ 25°C
Voltage: 6-110VDC and 6-277VAC.
Nominal Power:
DC Coils: 1.2 Watts.
AC Coils: 2.7VA.
Duty Cycle: Continuous.
Initial Insulation Resistance: 100 megohms, min.
Insulation: Class B, 130°C.
Coil Data
Nominal
Voltage
6
DC
12
Coils
24
48
110
6
12
AC
24
Coils
120
240
277
*±15% for AC coils.
DC
Resistance
in Ohms
± 10%*
32.1
120
472
1,800
10,000
4.2
18
72
1,700
7,200
10,250
Must
Operate
Voltage
4.5
9.0
18.0
36.0
82.5
5.1
10.2
20.4
102.0
204.0
235.5
Nominal
Coil
Current
(mA)
187
100
51
26.7
11
460
230
115
24
12
9
Operate Data @ 25°C
Must Operate Voltage:
DC Coils: 75% of nominal.
AC Coils: 85% of nominal.
Operate Time (Excluding Bounce): 20 milliseconds, typical, at nominal
voltage.
Release Time (Excluding Bounce): 20 milliseconds, typical, at nominal
voltage.
Environmental Data
Temperature Range: (Operating)
DC Coils: -45°C to +70°C.
AC Coils: -45°C to +45°C.
Shock: 15g’s, 11 ms (non-operating).
Vibration: .065" double amplitude, 10-55 Hz.
Mechanical Data
Termination: .250" quick connect/solder; and PC board.
Enclosure: Polycarbonate dust cover.
Weight: 3.2 oz. (92g) approximately.
Ordering Information
B Typical Part No.
KUHP- 11
A
5
1. Basic Series and Type:
KUHP = Enclosed 20/30 amp relay.
2. Contact Arrangement and Rating:
5 = 1C (SPDT); 30 amps.
11 = 2C (DPDT); 20 amps.
3. Coil Input:
A = AC, 50/60 Hz.
D = DC
4. Mountings:
1 = PLAIN CASE
5 = BRACKET MOUNT CASE
T = TOP FLANGE CASE
5. Terminals and Contact Materials:
1 = .250" (6.35mm) quick connect/solder; silver-cadmium oxide.
7 = .047" (1.19mm) printed circuit; silver-cadmium oxide.
6. Coil Voltage:
AC coils to 277VAC, 50/60 Hz.
DC coils to 110VDC.
NOTE: No sockets are available for this relay.
1 -120
Our authorized distributors are more likely to maintain the following items in stock for immediate delivery.
KUHP-5A51-24 KUHP-5AT1-120
KUHP-5A51-120 KUHP-5D51-12
KUHP-5D51-24
KUHP-5DT1-12
KUHP-5DT1-24
KUHP-11A51-24
KUHP-11A51-120
KUHP-11AT1-120
KUHP-11D51-12
KUHP-11D51-24
KUHP-11DT1-12
KUHP-11DT1-24
Dimensions are shown for
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
803
Refer to inside back cover.