English
Language : 

HC-2 Datasheet, PDF (1/1 Pages) Tyco Electronics – Make & Break Load Switching
Kilovac HC-2 No Load Switching
HC-4 Make & Break Load Switching
Kilovac HC-6 Make Only
8 kV
Features:
HC-2
• Vacuum dielectric and copper contacts for
high current carry rating of 25 Amps
• Not designed for power switching
• Stable, low contact resistance
• Meets requirements of MIL-R-83725
HC-4
• Tungsten contacts for long life in power
switching applications
• Vacuum dielectric for arc suppression when
making or breaking a load
• Widely used in defibillator applications
• Meets requirements of MIL-R-83725
Features:
• Tungsten contacts for switching high in-rush
loads
• SF-6 gas-filled for capacitive discharge
applications
• Ideal for ESD testing applications
PRODUCT SPECIFICATIONS
Part Number
Units
HC-2
Contact Arrangement ..........................................................
SPDT
Contact Form ........................................................................
C
Test Voltage (dc or 60Hz) ................................................... kV Peak
10
Rated Operating Voltage
dc or 60 Hz .....................................................................
2.5 MHz ...........................................................................
16 MHz ............................................................................
32 MHz ............................................................................
Continuous Carry Current , Maximum
dc or 60 Hz .....................................................................
2.5 MHz ...........................................................................
16 MHz ............................................................................
32 MHz ............................................................................
Coil Hi-Pot (V RMS, 60 Hz) ...........................................
Contact Capacitance
Between Open Contacts .................................................
Open Contacts to Ground ..............................................
Contact Resistance, Maximum ...........................................
Operate Time, Maximum .....................................................
Release Time, Maximum .....................................................
Shock, 11 ms 1/2 Sine ........................................................
Vibration, 10 G’s Peak .........................................................
Operating Ambient Temperature Range ............................
Mechanical Life (Operations x 106) ....................................
Weight, Nominal ..................................................................
A RMS
pF
ohms
ms
ms
Peak G's
Hz
oC
Cycles
oz.
8
-
-
-
25
-
-
-
500
-
-
0.01
6
6
50
55-2000
-55 to +125
2
1.4
* Contact resistance for gas-filled relays is measured at 28 Vdc, 1 amp
HC-4
SPDT
C
10
8
-
-
-
15
-
-
-
500
-
-
0.02
6
6
50
55-2000
-55 to +125
2
1.4
HC-6
SPDT
C
10
8
-
-
-
8
-
-
-
500
-
-
0.5*
6
6
50
55-2000
-55 to +125
1
1.4
COIL DATA
Nominal, Volts dc
12 26.5 115
Pickup, Volts dc, Maximum
8 16 80
Drop-Out, Volts dc
.5 - 5 1 - 10 5 - 50
Coil Resistance (Ohms ±10%) 80 335 6000
Ratings listed are for 25°C, sea level conditions
PART NUMBER SELECTION
Sample Part No. HC -
Model
2
4
6
Coil Voltage
Blank = 26.5 Vdc
/12Vdc = 12 Vdc
/115Vdc = 115 Vdc
6 /12Vdc
CII Technologies / P.O. Box 4422 / Santa Barbara, CA 93140 / ph 805.684.4560 / fax 805.684.9679 / e-mail info@kilovac.com / website www.ciitech.com