English
Language : 

H-18 Datasheet, PDF (1/1 Pages) Tyco Electronics – Make & Break Load Switching
Kilovac H-18 Make & Break Load Switching
8 kV
Features:
• Smallest DPDT high voltage relay
• Vacuum dielectric for power switching low
current loads
• 8 kV rating; carries 2 Amps at 32 MHz
• Tungsten contacts for power switching low
current loads
• Meets requirements of MIL-R-83725
Features:
PRODUCT SPECIFICATIONS
Part Number
Units
Contact Arrangement ..........................................................
Contact Form ........................................................................
Test Voltage (dc or 60Hz) ................................................... kV Peak
Rated Operating Voltage
kV Peak
dc or 60 Hz .....................................................................
2.5 MHz ...........................................................................
16 MHz ............................................................................
32 MHz ............................................................................
Continuous Carry Current , Maximum
Amps
dc or 60 Hz .....................................................................
2.5 MHz ...........................................................................
16 MHz ............................................................................
32 MHz ............................................................................
Coil Hi-Pot (V RMS, 60 Hz) ...........................................
Contact Capacitance
pF
Between Open Contacts .................................................
Open Contacts to Ground ..............................................
Contact Resistance, Maximum ...........................................
ohms
Operate Time, Maximum .....................................................
ms
Release Time, Maximum .....................................................
ms
Shock, 11 ms 1/2 Sine ........................................................ G's Peak
Vibration, 10 G’s Peak .........................................................
Hz
Operating Ambient Temperature Range ............................
oC
Mechanical Life (Operations x 106) ....................................
cycles
Weight, Nominal (oz) ..........................................................
oz.
H-18
DPDT
2C
10
8
5
3
2
10
7
3
2
500
0.8
1.5
0.02
15
15
30
55-500
-55 to +125
1
2.5
H-18
COIL DATA
Nominal, Volts dc
12 26.5 115
Pickup, Volts dc, Maximum
8
16 80
Drop-Out, Volts dc
.5 - 5 1 - 10 5 - 50
Coil Resistance (Ohms ±10%) 60 250 3500
PART NUMBER SELECTION
Sample Part No.
Model
H-18
Coil Voltage
Blank = 26.5 Vdc
/12Vdc = 12 Vdc
/115Vdc = 115 Vdc
H-18 /12Vdc
37
CII Technologies / P.O. Box 4422 / Santa Barbara, CA 93140 / ph 805.684.4560 / fax 805.684.9679 / e-mail info@kilovac.com / website www.ciitech.com