English
Language : 

FT600 Datasheet, PDF (1/2 Pages) Tyco Electronics – New surface-mount fuse products for overcurrent protection of communications equipment
Raychem FT600 Series Overcurrent Fuse
New surface-mount fuse products for overcurrent protection of communications equipment
Benefits:
• When combined with a SiBar™ overvolt-
age protection device, assists equipment
in meeting regulatory standards with no
additional series components
• Improved temperature rise performance
over other similar SMT fuse devices
under sneak current testing
• High density placement in multi-port
system designs
Target Applications:
• xDSL and ADSL linecards and modems
• T1/E1 systems
• Twisted pair telecom ports requiring
Telcordia GR-1089, UL60950 and FCC
Part 68 compliance
Features:
• The lightning robust surface-mount fuse
offers overcurrent protection from power
faults
• Designed to assist equipment in comply-
ing with telecom specifications including
UL60950, FCC Part 68, and Telcordia
GR-1089
• Small footprint and low resistance
• Low profile
Interrupt Voltage and Current Ratings
Part
Number
Ampere Rating
(A)
Voltage Rating
(V)
Typical Resistance
(Ω)
Typical I2t
(A2s)*
FT600-0500
0.50
250
0.5
1
FT600-1250
1.25
250
0.1
16
FT600-2000
2.00
250
0.05
18
The FTxxxx devices are designed to carry 100% of rated current for 4 hours minimum and 250% of rated current for 1 second minimum, 120 seconds maximum. Resistance measured at 10% of rated current.
*I2t is calculated at 10 ms or less.
GR-1089
1000Vac, 5A, 0.5sec
GR-1089
600Vac, 60A, 5sec
UL60950
600Vac, 40A, 1.5sec
GR-1089/UL60950
600Vac, 7A, 5sec
GR-1089/UL60950
600Vac, 2.2A, 30min
GR-1089
277Vac, 25A, 15min
FT600-0500
✓
✓
✓
✓
FT600-1250
✓
✓
✓
✓
✓
✓
FT600-2000
✓
✓
✓
✓
✓
✓
Note: FT600-1250 and FT600-2000 are designed to assist equipment in complying with Telcordia GR-1089 specifications. In-circuit testing is strongly recommended.
UL60950
120Vac, 25A, 30min
✓
✓
✓
Telcordia
GR-1089
Surge Voltage (Vpk)
Wave Form (µs)
Surge Current (A)
Repetitions (each polarity)
FT600-0500
FT600-1250
FT600-2000
First Level
Test 1
600
10x1000
100
25
✓
✓
First Level
Test 2
1000
10x360
100
25
✓
✓
First Level
Test 3
1000
10x1000
100
25
✓
✓
First Level
Test 4
2500
2x10
500
10
✓
✓
First Level
Test 5
1000
10x360
25
5
✓
✓
Second Level
Test 1
5000
2x10
500
1
✓
✓
FCC
Part 68
Type A
Metallic
Type A
Longitudinal
Type B
Metallic
Type B
Longitudinal
Surge Voltage (Vpk)
Short Circuit Wave Form (µs)
Surge Current (A)
Repetitions (each polarity)
800
10x560
100
1
1500
10x160
200
1
1000
5x320
25
1
1500
5x320
37.5
1
FT600-0500
Fuse open
Fuse open
✓
✓
FT600-1250
✓
✓
FT600-2000
✓
✓
✓
✓
✓
✓
The FT600-0500, FT600-1250 and FT600-2000 are designed to meet the FCC Part 68 lightning surge requirements. Note that Type A tests allow for an overcurrent protection component to fuse open during
the surge.
Product Dimensions
A
C
B
Dimensions in millimeters (inches)
A (Max.)
B (Max.)
C (Max.)
10.5 (0.413) 3.4 (0.133) 3.4 (0.133)
Termination material
Body material
Termination solderability
Solder heat withstand
Solvent resistance
Storage temperature
Storage humidity
Details
Silver-plated brass
Ceramic
Per IEC-60127-4
Per MIL-STD-202, Method 210, Test Condition J
Per MIL-STD-202F, Method 215J
-40/+85°C
Per MIL-STD-202F, Method 106F